HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)

GetStorageArray (subtarget=Filter)
GetStorageArray (subtarget=Filter) obtains information about the storage system for a
specific component.
Parameters
Table 65 GetStorageArray (subtarget=Filter) command parameters
DescriptionStatusParameter name
Specify Filter.
Required
subtarget
Object ID for a component (such as a path, port, or logical unit)
of the storage system
Information is displayed about the storage system for the
component identified by the object ID you specify with this
parameter. Specify the object ID obtained from another CLI
response. The value is encoded by the CLI.
Required
objectid
Parameter values to obtain in advance
None.
Command execution example
In this example, the GetStorageArray (subtarget=Filter) command obtains information about
the storage system for the logical unit (object ID: *****).
hdvmcli GetStorageArray -o "D:\logs\GetStorageArray_Filter.log"
subtarget=Filter objectID=*****
*****: The value is encoded by the CLI.
Command execution result
RESPONSE:
An instance of StorageArray
objectID=*****
name=XP1024@172.16.45.1
description=xxxxx
serialNumber=10001
arrayFamily=XP1024/128
arrayType=XP1024
microcodeVersion=21-03-00/00
agentVersion=02-05-14
productName=1024
controllerVersion=21-04-00-00/00
numberOfControllers=4
capacityInGB=3,839
cacheInMB=10,240
sharedMemoryInMB=-1
Command reference188