HP XP P9000 Tiered Storage Manager Software 7.6.1-00 Release Notes
If the logical group is deleted before deleting the schedule set for data placement profiles, the schedule
remains. When the scheduled date arrives, the task with the data placement profiles executes and
generates the KAIC15753-E error.
Manage Data Placement Profiles (Logical Group View) dialog box
In the performance chart of Manage Data Placement Profiles (Logical Group View) dialog box, the
information on profile operation history may be displayed outside the performance chart.
However, the proper information is displayed within performance chart.
If this occurs, adjust datetime in From to accommodate the information on profile operation history in
the performance chart.
Estimated time for the search inconsistency task (search inconsistent data placement
profile task)
The estimated time of a search inconsistency task is not displayed.
Storage system links in the Mobility tab
When a link concerning the following storage systems is clicked on the volume list of the logical group,
a KAIC16850-E error dialog box is displayed.
• XP12000/XP10000/SVS200
If the KAIC16850-E error dialog box is displayed, close the error dialog box.
To see information about the target storage system, see the Resource tab.
Migrating Mainframe THP volumes
If a Mainframe THP volume is migrated with optional shredding specified, the volume is not deleted
after the shredding. If necessary, delete the volume by using Element Manager.
The zero page reclaim option has no effect in migrations that have a Mainframe THP volume specified
as a source. The storage system automatically executes a zero page reclaim.
A tier created from the Device Manager GUI is not displayed in Tiered Storage Manager
When a tier created from the Device Manager GUI meets any of the following conditions, the tier is
not displayed in the storage tiers of Tiered Storage Manager:
• The tier was created by directly specifying 101 or more volumes.
• The tier was created by selecting either of the following attributes in the advanced search criteria
and by specifying 101 or more values for the attribute:
◦ ID/Number/Name is specified for the category, and the Parity group on a controller that
hosts can access is specified for the attribute.
◦ ID/Number/Name is specified for the category, and the Parity group on a controller that
contains drives is specified for the attribute.
Editing a storage tier created by the CLI in the Edit Tier dialog box
If a storage tier including the capacity conditions created by the CLI is selected and the Edit Tier dialog
box is launched, the GUI malfunctions.
In this case, use the CLI ModifyStorageTier command to edit the storage tier. Then close the GUI
browser and log in again.