HP XP P9000 Command View Advanced Edition Suite Software 7.6.0-00 Administrator Guide (Web Version)
The following table lists the Device Manager agent version required for each storage system
model.
Table 10 Device Manager agent version required for each storage system model when managing
copy pairs by using the CLI
Device Manager agent versionStorage system model
7.0 or laterP9500
5.7 or laterXP24000
5.8 or laterXP20000
1.0 or later
XP12000
XP10000
XP1024
XP128
Related topics
• System configuration for using the local management method to manage copy pairs, page 55
• System configuration for using the central management method to manage copy pairs, page 57
• System configuration for using a virtual command device server configuration to manage copy
pairs, page 59
• System configuration for using an SVP configuration to manage copy pairs (when copy pairs are
defined in a configuration definition file), page 61
• System configuration for using an SVP configuration to manage copy pairs (when copy pairs are
defined as a device group), page 62
Notes on managing copy pairs
Note the following when managing copy pairs:
• In the following cases, you need to modify the configuration definition file because copy pairs will
no longer be able to be managed from Device Manager:
• If the IP address of the host was changed when ipaddress is set for the server.horcmcon-
figfile.hostname property in the server.properties file of the Device Manager
server
• If the host name was changed when hostname is set for the server.horcmconfig-
file.hostname property in the server.properties file of the Device Manager server
To modify the configuration definition file, perform the following procedure:
1. Modify the configuration definition file of the local host.
2. Restart the Device Manager agent on the local host.
3. Modify the configuration definition file of the remote host.
4. Refresh the storage systems.
• If you want to use Device Manager to control copy pairs managed by RAID Manager, the config-
uration definition file on the host that manages the P-VOL of the copy pair and the configuration
definition file on the host that manages the S-VOL of the copy pair must have the same group name
and the same pair name. If different names are specified, Device Manager cannot control that
copy pair. In addition, if you want to use a single host to manage multiple copy pairs, make sure
System configuration and requirements68