HP XP P9000 Command View Advanced Edition Suite Software 7.6.0-00 Administrator Guide (Web Version)

SolutionProblem and causeNo.
3. If there are LDEVs that have not been migrated yet, re-
move the cause of the error, and then re-create and
execute the migration task.
Restore a backed up database.
PROBLEM: Tiered Storage Manager
operations cannot be performed
because an error occurred in the
database.
CAUSE: The repository cannot be
accessed because an error occurred
in the database.
4
Related topics
Starting services, page 191
Stopping services, page 192
Problems and solutions in the host
The following table lists common problems that occur on the Device Manager agent and describes
how to resolve them.
Table 101 Common problems and solutions on the Device Manager agent
SolutionProblemNo.
This message is output when multiple HiScan
commands are executed at the same time.
No action is required.
The following message was output
to the event log or the system log:
[HORCM_005] Could not
create endpoint for remote
connection.
1
The following message was output
to the event log or the system log:
[HORCM_007] Illegal
parameter values in HORCM
configuration file.
2
The LUN path to the volume managed by the Device
Manager recognized by the host has been disabled,
possibly due to a lost connection. Either restore the
disabled LUN path, or change the OS settings so that
the disabled LUN path is no longer recognized.
When executing the HiScan com-
mand, the KAIC22019-E error
message is output, and host inform-
ation cannot be registered on the
Device Manager server.
3
Another P9000 Command View AE Suite product
might have attempted to access the Device Manager
agent either immediately after the installation of the
Device Manager agent was complete, or immediately
after the Device Manager agent services started. Wait
a few minutes, and then retry the operation.
A communication error occurs, and
the processing of other P9000
Command View AE Suite products
stops.
4
Administrator Guide (Web Version) 277