HP StorageWorks P9000 Replication Manager Software 7.1.1-00 Release Notes (TB584-96041, September 2011)

If a task operation was performed and the path settings of the target volume of the task were
different from those specified when the task was created, the task operation generated the
RPM-00456 message.
If a single copy group contained 256 or more Simplex (SMPL) copy pairs, starting Change Pair
Status Wizard for that copy group might fail with the KAVN00433-E (RPM-00480) message.
Tasks that create a Continuous Access Journal (CAJ) copy pair or a task that would add a copy
pair to an existing CAJ copy group when Replication Manager version is below 7.1.1 generated
the KAVN00469-E (RPM-03304) error.
If copy groups that made up a multi-target or cascade configuration contain a different number
of pairs, the Pair Configuration Wizard generated the KAVN-00209-E message for copy pair
volumes in the copy group with fewer pairs.
Selecting a volume with multiple copy pair definitions and then starting Pair Configuration Wizard
generated the KAVN00561-E (RPM-00063) message.
If there was an iSCSI-connected LU on the pair management server, when an attempt was made
in Pair Configuration Wizard to perform a pair operation task for a copy group, the task might
not be successful. In addition, alerts might not be detected, or the My Copy Group display might
be incorrect.
If there was an iSCSI-connected LU on the pair management server, when a create operation that
reverses the copy direction was executed in Pair Configuration Wizard, the task succeeded but
the result was not reflected in the Configuration Information window.
If the task to create a replica for the SQL Server database or the command (CLI) to make a backup
of the database generated the KAVX1212-E message, the pair status might not change to PSUS
status and might remain in the PAIR status when the task or command (CLI) ends.
When attempting to open the JNLGs tab for the Continuous Access Journal secondary storage
systems in a 3DC delta resync configuration, if the resource group to which the user belonged
did not contain a Continuous Access Journal primary storage system, the attempt to display the
JNLG list tab might generate the KAVN00209-E message.
If Reverse Copy Direction option was enabled for a create operation in Change Pair Status
Wizard, when the task for that operation was run for a copy pair that was part of a copy group
whose configuration definition files for the primary volume and secondary volume were located
on separate pair management servers, the task generated the RPM-00500 message.
In a mainframe-based system, when selecting a copy pair that contained a volume for an XP24000
or XP20000 storage system, if the Replication Manager registered the Device Manager that
contained information about the volume to the information source, the Apply Open/MF CTG option
did not appear on 3. Select Pair Operation in Change Pair Status Wizard.
In an environment in which 3DC MxNxO was configured on a mainframe system, you could not
add a consistency group to a copy group container.
If the primary and secondary volumes of a remote copy pair had the same LDEV number, when
you tried to created or perform operations on a copy pair, it generated the RPM-00506 message,
and the copy pair status of the secondary volume became Unknown.
Execution of a task that added a copy pair to an existing copy group that had a CTGID generated
the KAVN00453-E (RPM-04601) message.
When selecting multiple volumes in Host view or Storage System view of LUNs, and then trying
to start Pair Configuration Wizard, it might generate the KAVN00561-E (RPM-00023) message.
When selecting multiple volumes in Host view of DEVNs - Paired or Storage System view of LDEVs-
Paired, and then trying to start Pair Configuration Wizard, it might generate the KAVN00561-E
(RPM-00023) message.
4 Fixes