HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1 CLI Reference Guide (TB581-96066, September 2011)

DescriptionAttribute
Address of the Fibre port (AL_PA)
For P9500, XP24000/XP20000, XP12000/XP10000/SVS200, or
XP1024/XP128, either of the following values is output:
00 or no value: Neither a Fibre port nor an FCoE port
01 - EF: Valid address (two-digit hexadecimal number)
fibreAddress
Fibre topology
topology
Display name of the port
displayName
Indicates whether LUN security is valid for the port.
true: Valid
false: Not valid
lunSecurityEnabled
Port controller ID
controllerID
Port option
No value is output if the option is invalid.
portOption
WWN of the port
This item is valid when the port is a Fibre port or an FCoE port.
worldWidePortName
Channel speed
-1: None
0: Automatic
1: 1 Gbps
2: 2 Gbps
4: 4 Gbps
8: 8 Gbps
channelSpeed
Port attribute
Target
RCU Target
Initiator
LCP
RCP
External: External port
No value: Unknown
portRole
SLPR number
-1 is output for storage systems that do not support SLPR.
slprNumber
PortController instance
The PortController instance is output when the following commands are executed:
GetStorageArray (subtarget=PortController) on page 158
CLI Reference Guide 319