HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

When an error occurs during batch functionality execution
This section explains how to take action if an error occurs during batch functionality execution.
When the target storage system is other than XP24000/XP20000, or is an XP24000/XP20000
whose microcode version is earlier than 60-02-00-00/00
If an error occurs during the batch functionality execution, perform the following procedure to check
up to what point the batch file content was processed. For the unprocessed commands, re-create the
batch file, and re-execute the batch functionality.
1. Execute the AddStorageArray command or RefreshStorageArrays command.
The path information from the host to the volume is updated.
2. Execute the GetStorageArray command to check which command lines in the batch file were
applied to the storage system.
The command processing during batch functionality execution is not performed in the order
described in the batch file. All lines need to be checked to determine which command lines in
the batch file were applied.
3. Delete the command lines applied to the storage system from the batch file.
4. Execute the batch functionality again.
When the target storage system is an XP24000/XP20000 whose microcode version is
60-02-00-00/00 or later
If an error occurs in the Device Manager server during batch functionality execution, the Device
Manager CLI error message is output as follows:
ERROR RESPONSE:
KAIC90083-E Device Manager Server Exception:
error code= code
error level= level
error source= source
description= description
Check the Device Manager server error code that is output in place of code and the storage system
error code that is output in place of description, and then take one of the following actions:
When the Device Manager server error code is other than 6400:
Perform the following procedure:
1. Execute the GetStorageArray command to check whether there is an error in the batch file.
2. Correct any error in the batch file.
3. Execute the batch functionality again.
When the Device Manager server error code is 6400:
When the error code of the storage system is one of the following values:
Device Manager CLI command reference344