HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 Administrator Guide (web) (TB581-96050, May 2011)
You can specify a value from 0 to 1440. If you specify 0, the Device Manager server does not check
whether the configuration of P9500 or XP24000/XP20000 is changed.
Default: 10 (minutes)
CAUTION:
If the GUI displays a warning message, manually refresh the corresponding storage system information.
You can also specify the settings so that information in the database is automatically updated in case
a user forgets to perform a manual refresh after changing the storage system configuration. To do
so, set up the following properties:
• server.dispatcher.daemon.autoSynchro.doRefresh property
• server.dispatcher.daemon.autoSynchro.type property
The Device Manager server cannot detect the following configuration change performed on P9500
or XP24000/XP20000:
• Creating, changing, or deleting copy pairs
• Changing the status of an LDEV (such as Normal, Blocked, or Copying)
• Changing the access attribute of an LDEV (such as Read/Write, Read Only, or Protect)
The Device Manager server treats the following operations as configuration changes of P9500 or
XP24000/XP20000:
• Restarting SVP
• Refreshing the configuration information of P9500 or XP24000/XP20000 displayed in Remote
Web Console.
• Switching the SVP in a cluster configuration from the executing node to the standby node, or vice
versa.
• Turning on the DKC
server.dispatcher.daemon.autoSynchro.doRefresh
This property specifies whether to automatically refresh the information of P9500 or XP24000/XP20000
in the database if the Device Manager server detects that the configuration of the P9500 or
XP24000/XP20000 has changed.
If true is specified for this property and a user does not perform a manual refresh after the Device
Manager server detects a change, the information of P9500 or XP24000/XP20000 in the database
is automatically refreshed at the interval specified in the
server.dispatcher.daemon.autoSynchro.type property. If false is specified, the database
is not automatically refreshed.
Default: true
CAUTION:
If you specify true, only the information about the P9500 or XP24000/XP20000 is updated in the
database. The information in the configuration file of a host that recognizes the command device of
P9500 or XP24000/XP20000 is not updated in the database.
Administrator Guide (Web Version) 315