HP P9000 Tiered Storage Manager Software 7.4.0-00 CLI Reference Guide (TB585-96027, December 2012)
Specifiable characters or valuesOperatorsProperty name
Simplex
P-VOL
S-VOL
=, <>
ContinuousAccessSynchronous
( ContinuousAccessXPSynchronous
)
For GetStorageArray
(subtarget=ArrayGroup) in Device
Manager CLI, specify the value displayed
for the displayName attribute of the
ArrayGroup object.
You can specify the following characters:
A to Z
a to z
0 to 9
Hyphen (-)
Underscore (_)
Period (.)
At sign (@)
Space character
Non-ASCII characters
If the operator is = or <>, commas (,) can
be used to specify multiple
ControllerArrayGroup names. The
maximum number of elements separated
by commas (,) is 100.
No more than 75 bytes can be specified
for each ControllerArrayGroup
name.
=, <>,
startsWith,
contains
ControllerArrayGroup
Specify this property in the following
format:
[logical-DKC-number:]CU-number:LDEV-number
Specify hexadecimal values that are less
than 0x100 and that are separated by
colons (:). A 0 at the beginning of the first
value can be omitted.
The following are specification examples:
• When omitting a logical DKC number:
Specify 2:0a or 02:0A.
• When specifying a logical DKC num-
ber: Specify 0:02:0a or 00:02:0A.
You can specify a list of values separated
by commas (,) or a range of values
separated by a hyphen (-).
The maximum number of elements
separated by commas (,) is 100.
The range separated by a hyphen (-) can
specify only 1 element.
=ControllerDeviceNumber
Yes
No
=
CVS
#1
CLI Reference Guide 43