HP P9000 Tiered Storage Manager Software 7.2.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
Version 7.2.0–00 Description This package is a new release of the HP P9000 Tiered Storage Manager Software. This release adds feature enhancements. For details, see “Enhancements” (page 3). Update recommendation Routine Supersedes 7.1.1–01 NOTE: When the full package of Device Manager 7.2.0–00 is applied, Tiered Storage Manager 7.2.0–00 is also applied automatically.
• If the configuration of a volume registered to a migration group was changed, an attempt to remove the volume from the migration group might have generated the KATS50243–E message. Additionally, an operation to delete the migration group might have generated the KATS50242–E message. • Relocation might not succeed when stop-monitoring tasks with relocation of the period is scheduled through a monitoring template.
3. Delete the failure status migration pair. Execute the DeleteMigrationPair command to delete the failure status migration pair. See the CLI command help for details about the DeleteMigrationPair command.
Determine the name of the storage system corresponding to the storage domain using one of the following methods: • Using the GUI: In the subwindow, on the Detailed Information tab, refer to the first value of Domain Ctrl. In Domain Ctrl, the display format of the storage system is ::. • Using the CLI: Refer to the controllerName value in the output of the GetStorageDomains -d command. Mozilla 1.7.
Starting the migration wizard When the migration wizard is started, do not start the migration wizard in more than five screens in the entire system. The following events might occur if the wizard is started in more than five screens: • Responses to the volumes search might take three minutes or more. • A memory shortage might occur because the amount of used memory (used, for example, by GUI processes and by the Web browser) increases greatly. If this occurs, restart the Device Manager server.