HP P9000 Command View Advanced Edition Suite Software 7.4.0-00 CLI Reference Guide (TB581-96326, December 2012)

Table Of Contents
commandDevice=false
commandDeviceEx=0
commandDeviceSecurity=false
chassis=2
arrayGroup=54
arrayGroupName=2-4-1
raidType=RAID5(3D+1P)
currentPortController=-1
defaultPortController=-1
isComposite=0
continuousAccessVolumeType=Simplex
businessCopyVolumeType=Simplex
snapshotVolumeType=Simplex
journalVolumeType=JNL-VOL
sysVolFlag=0
externalVolume=0
differentialManagement=false
snapshotPoolID=-1
journalPoolID=1
thpType=-1
consumedCapacityInKB=-1
thpPoolID=-1
threshold=-1
tcaPoolID=-1
thpPoolVolControlFlag=-1
managementAreaPoolID=-1
List of 1 PairedPool elements:
An instance of PairedPool
muNumber=0
pairedArrayType=Unknown
pairedSerialNumber=14053
pairedPoolID=1
.
. (repeated for other Pool instances)
.
*****: The values are encoded by the CLI.
GetStorageArray (subtarget=Port)
GetStorageArray (subtarget=Port) obtains the information about ports.
Parameters
Table 60 GetStorageArray (subtarget=Port) command parameters
DescriptionStatusParameter name
Specify Port.
Required
subtarget
Serial number of the storage system
If you omit this parameter, all the storage systems become the
target.
Optional
serialnum
Model of the storage system
If you omit this parameter, all the storage systems become the
target.
Optional
model