HP XC System Software Hardware Preparation Guide Version 4.0
Table 4-21 BIOS Settings for HP ProLiant DL145 G2 Nodes (continued)
Set to This ValueOption NameSubmenu NameMenu Name
Disabled
SIO COM Port
Enabled
PS/2 Mouse
Enabled
Console RedirectionConsole Redirection
Enabled
EMS Console
115.2K
Baud Rate
None
Flow Control
On
Redirection after BIOS
POST
DHCP
IP Address AssignmentIPMI/LAN Setting
Enabled
BMC Telnet Service
Enabled
BMC Ping Response
Enabled
BMC HTTP Service
Disabled
BIOS POST WatchdogIPMI
Set the following boot order on
all nodes except the head node:
1. CD-ROM
2. Removable Devices
3. PXE MBA V7.7.2 Slot 0300
4. Hard Drive
5. ! PXE MBA V7.7.2 Slot 0200 (!
means disabled)
Set the following boot order on
the head node:
1. CD-ROM
2. Removable Devices
3. Hard Drive
4. PXE MBA V7.7.2 Slot 0200
5. PXE MBA V7.7.2 Slot 0300
Boot
Disabled
Wake On Modem RingPower
Disabled
Wake On LAN
Table 4-22 provides the BIOS settings for ProLiant DL145 G3 nodes
Table 4-22 BIOS Settings for HP ProLiant DL145 G3 Nodes
Set to This ValueOption NameSubmenu NameMenu Name
Off
NumLockBoot OptionsMain
BMC
Serial Port ModeI/O Device ConfigurationAdvanced
Enabled
Serial port A:
3F8
Base I/O address:
IRQ 4
Interrupt:
AUTO
DRAM Bank InterleaveMemory Controller Options
Disabled
Node Interleave
4.7 Preparing the Hardware for CP4000 (AMD Opteron) Systems 89