HP XC System Software Release Notes for Version 3.1

Nagios 2.3.1
Copyright (c) 1999-2006 Ethan Galstad (http://www.nagios.org)
Last Modified: 05-15-2006
License: GPL
Reading configuration data...
Warning: Duplicate definition found for service 'nagiosmonitor'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 195)
Warning: Duplicate definition found for service 'hostmonitor'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 206)
Warning: Duplicate definition found for service 'syslogalertmonitor'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 217)
Warning: Duplicate definition found for service 'keysync'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 232)
Warning: Duplicate definition found for service 'sensorCollectionMonitor'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 252)
Warning: Duplicate definition found for service 'selmon'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 274)
Running pre-flight check on configuration data...
Checking services...
Warning: Service 'Syslog Alert Monitor' on host 'nh' has a notification interval
less than its check interval! Notifications are only re-sent after checks are made, so
the effective notification interval will be that of the check interval.
Warning: Service 'Syslog Alerts' on host 'nh' has a notification interval less
than its check interval! Notifications are only re-sent after checks are made, so the
effective notification interval will be that of the check interval.
Warning: Service 'System Event Log Monitor' on host 'nh' has a notification
interval less than its check interval! Notifications are only re-sent after checks
are made, so the effective notification interval will be that of the check interval.
Warning: Service 'Syslog Alert Monitor' on host 'n6' has a notification
interval less than its check interval! Notifications are only re-sent after checks are
made, so the effective notification interval will be that of the check interval.
Warning: Service 'Syslog Alerts' on host 'n6' has a notification interval
less than its check interval! Notifications are only re-sent after checks are made,
so the effective notification interval will be that of the check interval.
Warning: Service 'System Event Log Monitor' on host 'n6' has a notification
interval less than its check interval! Notifications are only re-sent after checks are
made, so the effective notification interval will be that of the check interval.
Warning: Service 'Syslog Alerts' on host 'n7' has a notification interval
less than its check interval! Notifications are only re-sent after checks are made,
so the effective notification interval will be that of the check interval.
Checked 49 services.
Checking hosts...
.
.
.
5.10 OVP Might Return LSF Errors
The Operation Verification Program (OVP) might return LSF errors if it is invoked too soon after
the spconfig utility is invoked.
This can occur because the spconfig utility adjusts the default two processor per node setting
to reflect more accurately the actual number of processors on each node. Thus, if the total processor
count changes as a result of invoking the spconfig utility, LSF may not have updated itself by
the time the OVP is invoked.
The OVP has two tests that confirm that SLURM and LSF are synchronized with respect to the
total number of processors, and these tests could fail.
5.11 OVP qsnet_database Test May Fail Due to Benign Errors Returned
By the qsctrl Utility
The following release note is specific to systems using the QsNet
II
interconnect.
In this release, it is not possible for the qsnet2 utilities to detect that a node is missing. Therefore,
the /usr/bin/qsctrl utility reports a warning message for all links in reset. For example:
# qsctrl
qsctrl: QR0N00:00:0:0 <--> Elan:0:0 state 3 should be 4
qsctrl: QR0N00:00:0:1 <--> Elan:0:1 state 3 should be 4
qsctrl: QR0N00:00:0:2 <--> Elan:0:2 state 3 should be 4
46 System Configuration