HP XC System Software Release Notes for Version 3.0
Enable the Acpi(HWP0002,700)/Pci(1|1)/Uart(9600
N81)/VenMsg(Vt100+) option.
1)
2) Enable the Acpi(HWP0002,700)/Pci(2|0) option.
3) If prompted, save the setting to NVRAM.
4) Enter x to return to the previous menu.
c. Select the Select Error Console option to enable console messages to be displayed on
the screen when you turn on the system.
1) Enable the Acpi(HWP0002,700)/Pci(1|1)/Uart(9600
N81)/VenMsg(Vt100+) option.
2) Enable the Acpi(HWP0002,700)/Pci(2|0) option.
3) Enter x to return to the previous menu.
4) If prompted, save the setting to NVRAM.
5) Enter x again to return to the previous menu
d. Select the System Reset option to reset the system and enter y to apply the changes.
12. Turn off power to the node:
a. Press Ctrl+b to exit console mode.
b. Enter CM to display the Command Menu.
c. Enter PC and enter off to turn off power to the node.
3.2.2 Preparing HP Integrity rx2620 and rx4640 Nodes
Perform the following hardware preparation tasks on each HP Integrity rx2620 and rx4640 server
in your HP XC system:
1. For each node in the system, ensure that the power cord is connected but that the CPU is
not turned on.
2. Follow this procedure to connect a personal computer (PC) to the Management Processor:
a. Connect a three-way DB9–25 cable to the MP DB-25 port on the back of the HP Integrity
rx2600 server.
b. Connect the CONSOLE connector to a null modem cable, and connect the null modem
cable to the PC COM1 port.
c. Use a terminal emulator, such as HyperTerminal, to open a terminal window.
d. Press the Enter key to access the MP. If there is no response, press the MP reset pin on
the back of the MP and try again.
e. Log in to the MP using the default user name and password shown on the screen. The
MP Main Menu is displayed.
3. Enter SL to show event logs. Then, enter C to clear all log files and Y to confirm.
4. Enter CM to display the Command Menu.
5. Enter UC and use the menu options to remove the default MP user name and password and
create your own unique user name and password. HP recommends setting your own user
name and password for security purposes.
The user name must have a minimum of 6 characters, and the password must have a
minimum of 8 characters. You must set the same user name and password on every node.
The user name and password are required to access the power management device and
console, for example, when you issue the console nodename command.
6. Enter PC (power cycle) and then enter on to turn on power to the node.
7. Press Ctrl+b to return to the MP Main Menu.
8. Enter CO to connect to the console.
3.2 Preparing the Hardware for CP6000 Systems 27