HP XC System Software Installation Guide Version 3.2

nodes ibblc64 and ibblc65 have an Exchange value of 2077.790000
12.5.2 OVP Reports Benign Nagios Warnings
The OVP might return the following Nagios warning messages. These messages are benign and
you can ignore them.
Verify nagios:
Testing configuration ...
Running basic sanity check on the Nagios configuration file.
Starting the command:
/opt/hptc/bin/nagios -v /opt/hptc/nagios/etc/nagios_local.cfg
Here is the output from the command:
Warnings were reported.
Nagios 2.3.1
Copyright (c) 1999-2006 Ethan Galstad (http://www.nagios.org)
Last Modified: 05-15-2006
License: GPL
Reading configuration data...
Warning: Duplicate definition found for service 'nagiosmonitor'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 195)
Warning: Duplicate definition found for service 'hostmonitor'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 206)
Warning: Duplicate definition found for service 'syslogalertmonitor'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 217)
Warning: Duplicate definition found for service 'keysync'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 232)
Warning: Duplicate definition found for service 'sensorCollectionMonitor'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 252)
Warning: Duplicate definition found for service 'selmon'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 274)
Running pre-flight check on configuration data...
Checking services...
Warning: Service 'Syslog Alert Monitor' on host 'nh' has a notification interval
less than its check interval! Notifications are only re-sent after checks are made, so
the effective notification interval will be that of the check interval.
Warning: Service 'Syslog Alerts' on host 'nh' has a notification interval less
than its check interval! Notifications are only re-sent after checks are made, so the
effective notification interval will be that of the check interval.
Warning: Service 'System Event Log Monitor' on host 'nh' has a notification
interval less than its check interval! Notifications are only re-sent after checks
are made, so the effective notification interval will be that of the check interval.
Warning: Service 'Syslog Alert Monitor' on host 'n6' has a notification
interval less than its check interval! Notifications are only re-sent after checks are
made, so the effective notification interval will be that of the check interval.
Warning: Service 'Syslog Alerts' on host 'n6' has a notification interval
less than its check interval! Notifications are only re-sent after checks are made,
so the effective notification interval will be that of the check interval.
Warning: Service 'System Event Log Monitor' on host 'n6' has a notification
interval less than its check interval! Notifications are only re-sent after checks are
made, so the effective notification interval will be that of the check interval.
Warning: Service 'Syslog Alerts' on host 'n7' has a notification interval
less than its check interval! Notifications are only re-sent after checks are made,
so the effective notification interval will be that of the check interval.
Checked 49 services.
Checking hosts...
.
.
.
12.5.3 OVP qsnet_database Test May Fail Due to Benign Errors Returned By the
qsctrl Utility
The following issue is specific to systems using the QsNet
II
interconnect.
In this release, it is not possible for the qsnet2 utilities to detect that a node is missing. Therefore,
the /usr/bin/qsctrl utility reports a warning message for all links in reset. For example:
12.5 Troubleshooting the OVP 175