HP XC System Software Installation Guide Version 3.0
# updateimage --gc 'nodename'
7. Follow the procedure described in the
HP XC System Software Administration Guide
to reimage the
node (by running the updateclient command).
For more information about SAN devices, see the storage array systems home page at:
http://h10018.www1.hp.com/wwsolutions/linux/products/storage/storagearray.html
Installing and Configuring the EVA3000 or EVA5000 SAN Storage Devices
The EVA3000 or EVA5000 SAN storage device is configured through a SAN appliance that provides a
browser interface for configuration. You do not need to install additional software on your cluster to allow
for the configuration of these devices. Information about the installation and configuration of the EVA3000
or EVA5000 is located at:
http://h10018.www1.hp.com/wwsolutions/linux/products/storage/storagearray.html
Note
The configuration procedure instructs you to present virtual disks as type Sun Solaris, which is incorrect.
Virtual disks must be presented as type Unknown.
Reboot all nodes connected to the SAN fabric to detect the volumes after device configuration is complete.
Making and Mounting the SAN Storage File Systems
After installing and configuring your SAN storage devices, follow this procedure to make and mount the
SAN storage devices onto your cluster:
1. Log in as the root user to the node on which the SAN controller (the HBA) was installed.
Note
If the SAN volume was not presented to the host before the host was booted, you must use the SAN
Management software to present the volume and reboot the host to proceed. If this is not done, any
attempt to mount the volume results in an error message that states it is not a valid block device.
2. View the following file to determine the devices that are related to the SAN volumes available to the
system:
# cat /proc/scsi/scsi
Command output looks similar to the following. In this example, lines containing Model: HSV110
indicate that the SAN was found on scsi2:
Attached devices:
Host: scsi0 Channel: 00 Id: 00 Lun: 00
Vendor: HP 36.4G Model: MAN3367MC Rev: HP05
Type: Direct-Access ANSI SCSI revision: 02
Host: scsi2 Channel: 00 Id: 00 Lun: 00
Vendor: COMPAQ Model: HSV110 (C)COMPAQ Rev: 2003
Type: Unknown ANSI SCSI revision: 02
Host: scsi2 Channel: 00 Id: 00 Lun: 02
Vendor: COMPAQ Model: HSV110 (C)COMPAQ Rev: 2003
Type: Direct-Access ANSI SCSI revision: 02
Host: scsi2 Channel: 00 Id: 00 Lun: 03
Vendor: COMPAQ Model: HSV110 (C)COMPAQ Rev: 2003
Type: Direct-Access ANSI SCSI revision: 02
Host: scsi2 Channel: 00 Id: 01 Lun: 00
Vendor: COMPAQ Model: HSV110 (C)COMPAQ Rev: 2003
Type: Unknown ANSI SCSI revision: 02
Host: scsi2 Channel: 00 Id: 01 Lun: 02
Vendor: COMPAQ Model: HSV110 (C)COMPAQ Rev: 2003
Type: Direct-Access ANSI SCSI revision: 02
Host: scsi2 Channel: 00 Id: 01 Lun: 03
74 Configuring SAN Storage Devices