HP XC System Software Hardware Preparation Guide Version 3.0

Table 3-4 iLO Settings for HP ProLiant DL360 G4 and DL380 G4 Nodes
Set To This ValueOption NameSubMenu NameMenu Name
Create a common iLO user name and password for every
node in your system. The password must have a minimum of
8 characters by default, but this value is configurable.
The user Administrator is predefined by default, but you
must create your own user name and password. For security
purposes, HP recommends that you delete the
Administrator user.
This user name and password are required to access the
console port with the telnet cp-nodename command.
AddUser
OnDHCP EnableDNS/DHCPNetwork
115200 (Press the F10 key to save the setting).Serial CLI Speed
(bits/seconds)
CLISettings
3. Select File > Exit to exit the Integrated Lights Out Setup Utility and resume the
power-on self-test.
4. Watch the screen carefully, and press the F9 key when prompted to access the ROM-Based Setup
Utility (RBSU).
Perform the following hardware preparation tasks from the RBSU for each node in your HP XC system:
1. Make the following settings from the RBSU main menu:
Table 3-5 BIOS Settings for HP ProLiant DL360 G4 and DL380 G4 Nodes
Set To This ValueOption NameMenu Name
On the head node, set the boot order so that the
CD-ROM is listed before the hard disk.
Set the following boot order on all other nodes;
CD-ROM does not have to be first in the list, but it
must be listed before the hard disk:
Standard Boot Order IPL
1. CD-ROM
2. NIC1
3. Hard Disk
DisableProcessor Hyper_threadingAdvanced Options
COM2Embedded Serial PortSystem Options
COM1
Press the Esc key to return to the main menu.
Virtual Serial Port
COM1BIOS Serial COnsole PortBIOS Serial Console &
EMS
115200BIOS Serial Console Baud Rate
DisableEMS Console
Command-Line
Press the Esc key to return to the main menu.
BIOS Interface Mode
2. Make any other BIOS settings at this time. Specific instructions for this task are outside the scope of this
document because the information depends on the hardware involved. You can find more information
on other BIOS settings in the appropriate
HP ProLiant Server User Guide
.
3. Press the Esc key to exit the RBSU. Press the F10 key to confirm your choice and restart the boot
sequence.
4. Repeat this procedure for every node in your HP XC system.
On hardware models such as the HP ProLiant DL360 G4 and DL380 G4 with smart array cards, you must
add the disk or disks to the smart array before attempting to image the node.
To do so, watch the screen carefully during the power on self-test phase of the node, and press the F8 key
when prompted to configure the disks into the smart array.
36 Preparing Individual Nodes