HP XC System Software Switching From the OFED Software Stack To the Voltaire Software Stack HowTo Version 3.
© Copyright 2007 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice.
Table of Contents Switching From the OFED Software Stack To the Voltaire Software Stack...................7 1 Minimum Requirements......................................................................................................................7 2 Impact...................................................................................................................................................7 3 Before You Begin.......................................................................................
List of Tables 1 2 Minimum Requirements.................................................................................................................7 Impact To the System......................................................................................................................
Switching From the OFED Software Stack To the Voltaire Software Stack This HowTo describes the process to switch HP XC System Software from the default OpenFabrics Enterprise Distribution (OFED) InfiniBand software stack to the Voltaire InfiniBand software stack. 1 Minimum Requirements Table 1 lists the minimum requirements to accomplish this task. Table 1 Minimum Requirements Component Minimum Requirement Installed version of the HP XC System Software Version 3.
# stopsys 2. Reimage all nodes: # setnode --resync --all 3. Clear out the configuration and management database (CMDB): # reset_db 4. Clear out the golden image directory: # rm -fr /var/lib/systemimager/images/base_image 5. Uninstall the OFED software packages: # /usr/voltaire/uninstall.sh NOTE: If the /usr/voltaire/uninstall.sh script generates errors, and the /usr/sbin/ofed_uninstall.sh script still exists, run the /usr/sbin/ofed_uninstall.sh script to complete the removal of the OFED software.
6 Troubleshooting If you need information about troubleshooting the Voltaire InfiniBand software stack, see Chapter 20 in the HP XC System Software Administration Guide. 7 HP Encourages Your Comments HP encourages you to provide comments about this document because HP is committed to providing documentation that meets your needs. Send any errors found, suggestions for improvement, or compliments to the following address: feedback@fc.hp.