6.3 HP IBRIX X9720/StoreAll 9730 Storage Administrator Guide (AW549-96073, June 2013)
4. Perform the flash operation by entering the following command and then go to step 5:
hpsp_fmt -flash -c <components-name> --force
5. If the components require a reboot on flash, failover the FSN for continuous operation as
described in the following steps:
NOTE: Although the following steps are based on a two-node cluster, all steps can be used
in a multiple node clusters.
a. Determine whether the node to be flashed is the active Fusion Manager by enter the
following command:
ibrix_fm -i
b. Perform a manual FM failover on the local node by entering the following command from
the active Fusion Manager:
ibrix_fm -m nofmfailover server1
The FM failover will take approximately one minute.
c. If server1 is not the active Fusion Manager, proceed to step e to fail over server1 to
server2.
d. To see which node is now the active Fusion Manager, enter the following command:
ibrix_fm -i
e. Move to your new active Fusion Manager node, and then enter the following command
to perform the failover:
ibrix_server -f -p -h server1
Steps for upgrading the firmware 139