6.2 HP IBRIX 9300/9320 Storage Administrator Guide (AW549-96049, December 2012)
CPU Information
===============
Cpu(System,User,Util,Nice) Load(1,3,15 min) Network(Bps) Disk(Bps)
-------------------------- ---------------- ------------ ---------
0, 0, 0, 0 0.09, 0.05, 0.01 1295 1024
Memory Information
==================
Mem Total Mem Free Buffers(KB) Cached(KB) Swap Total(KB) Swap Free(KB)
--------- -------- ----------- ---------- -------------- -------------
8045992 4190584 243312 2858364 14352376 14352376
Version/OS Information
======================
Fs Version IAD Version OS OS Version Kernel Version Architecture Processor
---------- ----------- ------------ ------—------—------—------—------—------—------—------—------
--- ------------ ---------
6.2.338(internal rev 130683 in SVN) 6.2.338 GNU/Linux Red Hat Enterprise Linux Server release 5.5
(Tikanga) 2.6.18-194.
el5 x86_64 x86_64
Remote Hosts
============
Host Type Network Protocol Connection State
------- ------ ---------- -------- ----------------
bv18-03 Server 10.10.18.3 true S_SET S_READY S_SENDHB
bv18-04 Server 10.10.18.4 true S_NEW
Check Results
=============
Check : bv18-04 can ping remote segment server hosts
====================================================
Check Description Result Result Information
------------------------------ ------ ------------------
Remote server bv18-03 pingable PASSED
Check : Iad's monitored nics are pingable
=========================================
Check Description Result Result Information
--------------------------------------------------- ------ ------------------
User nic bv18-04/bond1:2 pingable from host bv18-03 PASSED
Check : Physical volumes are readable
=====================================
Check Description Result Result Information
--------------------------------------------------------------- ------ ------------------
Physical volume 0wndzX-STuL-wSIi-wc7w-12hv-JZ2g-Lj2JTf readable PASSED /dev/mpath/mpath2
Physical volume aoA402-I1ek-G9B2-HHyR-H5Y8-eexU-P6knhd readable PASSED /dev/mpath/mpath1
Physical volume h7krR6-2pxA-M8bD-dkdf-3PK7-iwFE-L17jcD readable PASSED /dev/mpath/mpath0
Physical volume voXTso-a2KQ-MWCN-tGcu-1OBs-ejWG-YrKLEe readable PASSED /dev/mpath/mpath3
Check : Iad and Fusion Manager consistent
=========================================
Check Description
Result Result Information
------------ ------ ------------------
bv18-03 engine uuid matches on Iad and Fusion Manager PASSED
bv18-03 IP address matches on Iad and Fusion Manager PASSED
bv18-03 network protocol matches on Iad and Fusion Manager PASSED
bv18-03 engine connection state on Iad is up PASSED
bv18-04 engine uuid matches on Iad and Fusion Manager PASSED
bv18-04 IP address matches on Iad and Fusion Manager PASSED
bv18-04 network protocol matches on Iad and Fusion Manager PASSED
bv18-04 engine connection state on Iad is up PASSED
ibrixFS file system uuid matches on Iad and Fusion Manager PASSED
ibrixFS file system generation matches on Iad and Fusion Manager PASSED
ibrixFS file system number segments matches on Iad and Fusion Manager PASSED
ibrixFS file system mounted state matches on Iad and Fusion Manager PASSED
Superblock owner for segment 4 of filesystem ibrixFS on bv18-04 matches
nl
on Iad and Fusion Manager PASSED
Superblock owner for segment 3 of filesystem ibrixFS on bv18-04 matches
nl
on Iad and Fusion Manager PASSED
Superblock owner for segment 2 of filesystem ibrixFS on bv18-04 matches
nl
on Iad and Fusion Manager PASSED
Superblock owner for segment 1 of filesystem ibrixFS on bv18-04 matches
nl
on Iad and Fusion Manager PASSED
Viewing logs
Logs are provided for the Fusion Manager, file serving nodes, and 9000 clients. Contact HP
Support for assistance in interpreting log files. You might be asked to tar the logs and email them
to HP.
Viewing logs 79