HP X5000 G2 Network Storage System Administrator Guide
Replacing the EMU module
1. Insert the replacement EMU module and ensure the release lever locks in place (Figure 71
(page 82)).
Figure 71 Installing the EMU
2. Plug the cables back into the EMU module.
3. Verify that the new component is working properly by checking the associated LED status.
4. Confirm the firmware version.
5. Obtain an IP address.
IMPORTANT: Some of the configuration information is automatically repopulated, but you
must reconfigure the network settings and password.
6. Confirm that the system has resumed normal operations.
NOTE: This may take approximately one minute, or the time it takes for the Enclosure Manager
to boot.
Removing and replacing the server blade backplane
Removing the server blade backplane
1. Verify the failed component as described in “Verifying component failure” (page 66).
2. Power off the system as described in “Powering the storage system off and on” (page 60).
3. Remove the enclosure from the rack as described in “Removing the system enclosure from the
rack” (page 67).
4. Remove the top back panel by pressing the panel release button and lifting the latch to slide
the top back panel off.
5. Remove the midplane board as described in “Removing the midplane board” (page 70).
6. Remove the small baffle from beside the server blade backplane by pinching the tabs and
lifting the small baffle out of the enclosure.
7. Remove the large baffle from the bottom of the enclosure.
82 Removing and replacing hardware components