HP StoreEasy 3000 Storage Administrator Guide

DefinitionStatusLEDItem
Removing the drive does not cause a logical drive to fail.Off
The drive is a member of one or more logical drives.Solid greenDrive status4
The drive is rebuilding or performing a RAID migration,
stripe size migration, capacity expansion, or logical drive
extension, or is erasing.
Flashing green
The drive is a member of one or more logical drives and
predicts the drive will fail.
Flashing amber/green
The drive is not configured and predicts the drive will fail.Flashing amber
The drive has failed.Solid amber
The drive is not configured by a RAID controller.Off
Systems Insight Display LED combinations
When the health LED on the front panel illuminates either amber or red, the server is experiencing
a health event. Combinations of illuminated Systems Insight Display LEDs, the system power LED,
and the health LED indicate system status.
Table 1 Systems Insight Display LEDs and internal health LED combinations
StatusSystem power LEDHealth LEDSystems Insight
Display LED and
color
One or more of the following conditions may exist:AmberRedProcessor (amber)
Processor in socket X has failed.
Processor X is not installed in the socket.
Processor X is unsupported.
ROM detects a failed processor during POST.
Processor in socket X is in a pre-failure condition.GreenAmber
One or more DIMMs have failed.GreenRedDIMM (amber)
DIMM in slot X is in a pre-failure condition.GreenAmber
The Health Driver has detected a cautionary temperature
level.
GreenAmberOver temp (amber)
The server has detected a hardware critical temperature
level.
AmberRed
The PCI riser cage is not seated properly.GreenRedPCI riser (amber)
One fan has failed or is removed.GreenAmberFan (amber)
Two or more fans have failed or are removed.GreenRed
One or more of the following conditions may exist:AmberRedPower supply
(amber)
Only one power supply is installed and that power
supply is in standby.
Power supply fault
System board fault
One or more of the following conditions may exist:GreenAmber
Redundant power supply is installed and only one
power supply is functional.
AC power cord is not plugged into redundant power
supply.
Hardware components 13