HP WebQoS Administration Guide
Setup
WebQoS Configuration Files
Chapter 226
times) can be configured for a template by selecting the Advanced tab
and then Corrective Actions Policy Details.
SCA Parameters
The following parameters affect the SCA only. If you change any of these
parameters, you must restart the SCA.
These parameters impact measurement log files. In UNIX, the
measurement log files are located in the /var/opt/webqos/measures
directory. In Windows, these files are located in the
<install-directory>
\measures directory.
• LogInterval (minutes)
Default: 30
Range: >=1
How often, in minutes, WebQoS logs measurements to a log file. The
LogOn parameter must be enabled (set to 1) before WebQoS logs
measurements to the log file.
• LogOn
Default: 0 (disabled)
Range: 0 (disabled) or 1 (enabled)
Enable or disable measurement logging. To enable measurement
logging, set this parameter to 1. To disable measurement logging, set
this parameter to 0.
WebQoS creates a new measurement log file daily for each WebQoS
site. The measurement log file name is the site name you entered in
the management console followed by the date. The log file contains
performance measurements collected during the day for the site
including:
— Average response time for each request class
— Number of new,redirected, deferred, and rejected sessions for each
request class
• SaveFiles
Default: 0 (disabled)
Range: 0 (disabled) or 1 (enabled)
Enable or disable saving measurement log files. If enabled, all
measurement log files are saved. If disabled, measurement log files