HP WebQoS Administration Guide

Troubleshooting
Troubleshooting on Windows
Chapter 8 115
Error Messages Viewable From the Management
Console
The following error messages appear in popup windows in the
management console:
The SCI on <machine> on port <number> is not running.
The WebQoS SCI is down. You need to exit the management console,
restart the SCI on the WebQoS Management Server (see “Restarting
Individual WebQoS Components” on page 30), then restart the
management console.
Problems writing to the SCI socket.
The WebQoS SCI is down. You need to exit the management console,
restart the SCI on the WebQoS Management Server (see “Restarting
Individual WebQoS Components” on page 30), then restart the
management console.
Problems connecting to the SCI on <machine>. Unknown
hostname.
The machine that contains the SCI may be down or the network is
unreachable. Also, the intended machine may be mistyped or
unknown to the name server. Do the following:
1. Verify network connectivity. Run ping <machine>. If there is no
response, then check the Network connections from the Control
Panel.
2. Verify the name server configuration for your network in the
Control Panel
This new threshold put the set of thresholds out of order.
At least one threshold won’t be violated until a higher
priority threshold is violated. You may wish to edit it
later to change its priority.
Misconfiguration of threshold rules.
Fix: Ensure that the lower priority threshold rule is violated after the
higher priority rule.