HP VMA-series Memory Array Installation and Service Guide

Chapter 5 - Operating the System via the CLI
94
VMA-series Memory Array Installation and Service Guide
HP-AM456-9002A Rev 01
3. At the context prompt, type:
The command displays information similar to the following:
Displaying Fan Status
Display the status of the system fans for maintenance and troubleshooting
purposes. The fans are located in two fan trays designated as
1
(top) and
2
(bottom), and the fans are designated as
Left
,
Center
, and
Right
.
To display the current status of the fans:
1. Log into the Memory Array
2. Navigate to the desired
Fan
context level. At the root prompt, type:
Where:
3. At the context prompt, type:
Where:
show vimm-summary
chassis board 0> show vimm-summary
num-vimms 42
installed-vimm-ids 3-8,12-18,22-27,35,38-45,48,60,64-69,71,75,76,78-80
flash-vimm-ids 3-8,12-18,22-27,35,38-45,48,60,64-69,71,75,76,78-80
admin-down-vimm-ids 39
installed-mem-raw 2886.2GB (2688GiB)
usable-mem-raw 2199.0GB (2048GiB)
parity-mem-raw 549.8GB ( 512GiB)
spare-mem-raw 68.7GB ( 64GiB)
unavailable-mem-raw 68.7GB ( 64GiB)
formatted-percentage 78.1%
usable-mem-formatted 1718.0GB (1600GiB)
context chassis fan-tray {1 | 2}
1 Specifies the top fan tray.
2 Specifies the bottom fan tray.
show fan {left | center | right}
left Specifies the left fan in the specified fan tray.
center Specifies the center fan in the specified fan tray.
right Specifies the right fan in the specified fan tray.