HP VMA SAN Gateway for VMA-series Memory Arrays Release Notes - May 2012 - Software OE version G5.1.0

13
Additional platform/OS specific considerations
The following sections provide additional server platform and operating system specific supported
configuration considerations and recommendations.
HP-UX 11i v3
The Integrity Superdome 2 and BL8x0c i2 server blades require HP-UX 11i v3 update 10 (fusion
1203) or newer when connecting to the VMA SAN Gateway with VMA-series Memory Arrays. The
following subsections describe additional limitations and considerations when using HP-UX 11i v3.
Must Use Agile View No Legacy View Support
The VMA SAN Gateway is only supported with the ‘Agile View’ and Persistent DSFs of HP-UX 11i v3
Mass Storage Stack. The VMA SAN Gateway does not support SCSI Volume Set Addressing and
therefore is not supported with the Legacy View mode of HP-UX 11i v3. This is because the VMA
SAN Gateway only supports the de facto standard Peripheral Device Addressing (PDA) mode.
Legacy mode requires Volume Set Addressing (VSA) for targets which support greater than 8 LUNs
(LUN IDs 0-7) attached. The ‘Agile View’ of HP-UX 11i v3 Mass Storage Stack supports both PDA
and VSA addressing modes for storage devices and also provides I/O and connectivity support well
beyond 11i v2 limits. The backward compatible ‘Legacy View’ support delivered with HP-UX 11i v3
is scheduled to be deprecated with the next major release of HP-UX.
Similarly you must only use the ‘Agile View’ capabilities of management utilities such as System
Management Homepage (SMH) when managing LUNs created on the VMA array so that all LUNs
beyond LUN ID 7 are viewable and manageable.
Do Not Create a LUN 0 on the VMA Array
One of the values of HP-UX, especially the 11i v3 release, is commitment and focus on data integrity.
With 11i v3 and ability to bind DSFs to LUN WWIDs, we are also able to ensure that when a storage
device/LUN replacement is made that it is intentional. If there is a device with a new LUN WWID
connected to where a device was previously connected and only the LUN WWID has changed, HP-
UX 11i v3 asks for authorization to allow that replacement of device before allowing access,
especially writing to it, which could cause accidental data loss if it was not the correct device nor
intended to be a replacement device. For this reason it is recommended to not explicitly configure a
LUN ID 0 on the VMA SAN Gateway as any change or inability to access the created LUN 0 could
cause inaccessibility to all LUNs and stored data.
Queue-Depth Settings Using TPCC with HP-UX 11i v3
It is highly recommended to use the Target Port Congestion Control (TPCC) feature available with the
HP-UX 11i v3 Mass Storage Stack to manage and control I/O queue depth with the VMA SAN
Gateway. For additional information and usage of TPCC, see the “HP-UX 11i v3 Congestion Control
Management for Storage White Paper” available at:
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c02054623/c02054623.pdf
Use the following table to determine appropriate TPCC settings with HP-UX 11i v3 for your
environment:
Table 3. HP-UX 11i v3 TPCC queue depth values.
IF
THEN TPCC Setting is
I/Os are 4KB aligned and < 256KB 1024 / number of servers*
I/Os are 4KB aligned and > 256KB 512 / number of servers*