HP Remote Graphics Software 6.0 User Guide

Receiver network properties
Rgreceiver.Network.Timeout.IsMutable=bool
If set to 1, the user can modify all network timeout values in the RGS Receiver Control Panel. If set to
0, the user cannot modify the values. This property can be used to permanently set network timeouts
before the RGS Receiver is started. The default value is 1—timeout values are changeable by the
user.
Rgreceiver.Network.Timeout.IsGuiEnabled=bool (1)
This property allows the user to disable a visual notification when the network has timed out. When
the Rgreceiver.Network.Timeout.IsGuiEnabled property is set to 1 the network timeout is shown.
When the Rgreceiver.Network.Timeout.IsGuiEnabled property is set to 0 the visual network timeout
notification is not shown. See
Receiver network timeouts on page 148 for more details.
Rgreceiver.Network.Timeout.Warning=int 2000
Rgreceiver.Network.Timeout.Warning.IsMutable=int 1
The timeout in milliseconds used to detect and notify the user of a network disruption. The default
value is 2,000 milliseconds (2 seconds).
Rgreceiver.Network.Timeout.Error=int 30000
Rgreceiver.Network.Timeout.Error.IsMutable=int 1
The timeout in milliseconds used to detect and disconnect an inactive connection. The default value
is 30,000 milliseconds (30 seconds).
Rgreceiver.Network.Timeout.Dialog=int 15000
Rgreceiver.Network.Timeout.Dialog.IsMutable=bool 1
This property specifies the timeout in milliseconds used to display, and wait on responses from, input
dialogs, such as the authorization dialog and the PAM authentication dialog. The default value is
15,000 milliseconds (15 seconds).
Rgreceiver.Network.ProxyEnabled=bool 1
Rgreceiver.Network.ProxyPort=int 8080
Rgreceiver.Network.ProxyAddress=string (web-proxy.yourownserver.com)
These properties allow you to configure proxy settings, which are required to activate advanced
features of RGS such as Advanced Video Compression and HP Velocity.
Receiver hotkey properties
Rgreceiver.Hotkeys.IsMutable=bool 1
If set to 1, all Hotkey settings in the Receiver Control Panel can be changed by the user. If set to 0,
none of the hotkey settings can be changed by the user. This property can be used to permanently
enable or disable hotkey settings before the RGS Receiver is started. The default value is 1—hotkeys
can be changed by the user.
Rgreceiver.Hotkeys.IsSetupModeEnabled=bool (1)
This property allows the user to completely disable all hotkeys. When the
Rgreceiver.Hotkeys.IsSetupModeEnabled property is set to 1 the hotkeys will work as normal. When
the Rgreceiver.Hotkeys.IsSetupModeEnabled property is set to 0 all hotkeys are disabled. In other
words pressing the hotkey sequence will not do anything. See
Hotkeys tab on page 62 for more
details.
RGS Receiver properties 129