HP Remote Graphics Software 6.0 User Guide

This property allows the user to enable a warning dialog when closing the RGS window while RGS is
still connected. This warning dialog will warn the user that disconnecting from RGS while they are still
logged in will not log the user out of the remote system.
Receiver experience properties
Rgreceiver.Experience.IsMutable=bool 1)
When set to 1, the default, the user can turn this feature on and off in the Receivers Advanced >
General tab, Experience section. Setting to 0 disables the user's ability to turn the feature on and off.
Rgreceiver.Experience.Mode=FixedImageQuality | AdjustImageQuality
This property allows the user to set the startup behavior for the interactive experience controls.
FixedImageQuality is the default. AdjustImageQuality will cause RGS to use the settings for Minimum
image quality and Minimum update rate and adjust the image if needed.
Rgreceiver.Experience.MinImageQuality=int (20)
Controls the startup value for image quality if AdjustImageQuality is enabled. The minimum image
quality specifies the lowest quality level that will be used during the automatic adjustment. The
minimum image quality is absolute - the system will not lower quality below the specified value.
Values are from 0 to 100 with a default of 20.
Rgreceiver.Experience.MinUpdateRate=int (30)
Controls the startup value for minimum update rate if AdjustImageQuality is enabled. The minimum
update rate controls how aggressively the image quality is reduced. Specifying a minimum update
rate of 30 will drive the most aggressive quality reduction. The minimum update rate is a target. The
available bandwidth may be too low to maintain the target rate. Values are from 0 to 30 with a default
of 30.
Receiver browser properties
Rgreceiver.Browser.IsMutable=bool 1
This property only applies to the Linux RGS Receiver. If set to 1, the name of the browser used to
display online help can be changed by the user in the Receiver Control panel. If set to 0, the name of
the browser cannot be changed by the user.
Rgreceiver.Browser.Name=string mozilla
Rgreceiver.Browser.Name.IsMutable=bool 1
This property only applies to the Linux RGS Receiver, and can be used to set the name of the
browser to display online help. For example, setting Rgreceiver.Browser.Name=mozilla will start the
Mozilla browser when the Help button is clicked in the Receiver Control Panel.
For the Windows Receiver, the Help system is based on a CHM file.
Receiver audio properties
Rgreceiver.Audio.IsMutable=bool 1
If set to 1, the user will be able to modify all audio controls in the RGS Receiver. If set to 0, none of
the audio controls can be modified by the user. The default value is 1—the audio controls can be
modified by the user.
Rgreceiver.Audio.IsEnabled=bool 1
Rgreceiver.Audio.IsEnabled.IsMutable=bool 1
126 Chapter 8 RGS properties