HP Integrity Virtual Machines 4.3: Installation, Configuration, Administration

8.13 HP AVIO Stor EFI Driver Enumeration Policy
The default enumeration policy of the “HP AVIO Stor EFI Driver” is to enumerate boot LUNs.
Use the drvcfg EFI utility to change the enumeration policy to do the following:
Enumerate boot LUNs only.
Enumerate all LUNs.
The following example shows how to change the enumeration policy to enumerate boot LUNs
only:
Shell> drvcfg -s
HP AVIO Stor Driver Configuration
==================================
Enumerate only boot LUNs (Y/N)? [N]:Y
Drv[2F] Ctrl[ALL] Lang[eng] - Options set. Action Required is None
None
None
Shell>
Reset the guest for the change to take effect
vMP MAIN MENU
CO: Console
CM: Command Menu
CL: Console Log
SL: Show Event Logs
VM: Virtual Machine Menu
HE: Main Help Menu
X: Exit Connection
[g1] vMP> CM
(Use Ctrl-B to return to vMP main menu.)
[g1] vMP:CM> RS
At next boot only boot LUN will be enumerated
Use ^ and v to change option(s). Use Enter to select an option
Loading.: EFI Shell [Built-in]
EFI Shell version 1.10 [14.62]onsole - - - - - - - - - - - -
Device mapping table
fs0 : Acpi(PNP0A03,0)/Pci(0|0)/Scsi(Pun0,Lun0)/HD(Part1,SigBEC59C34-E6C8-11DB-8002-D6217B60E588)
fs1 : Acpi(PNP0A03,0)/Pci(0|0)/Scsi(Pun0,Lun0)/HD(Part3,SigBEC59C70-E6C8-11DB-8004-D6217B60E588)
blk0 : Acpi(PNP0A03,0)/Pci(0|0)/Scsi(Pun0,Lun0)
blk1 : Acpi(PNP0A03,0)/Pci(0|0)/Scsi(Pun0,Lun0)/HD(Part1,SigBEC59C34-E6C8-11DB-8002-D6217B60E588)
blk2 : Acpi(PNP0A03,0)/Pci(0|0)/Scsi(Pun0,Lun0)/HD(Part2,SigBEC59C52-E6C8-11DB-8003-D6217B60E588)
blk3 : Acpi(PNP0A03,0)/Pci(0|0)/Scsi(Pun0,Lun0)/HD(Part3,SigBEC59C70-E6C8-11DB-8004-D6217B60E588)
startup.nsh> echo -off
setting hpux path(\EFI\HPUX)...
type 'fs[x]:' where x is your bootdisk (0, 1, 2...)
type 'hpux' to start hpux bootloader
8.13 HP AVIO Stor EFI Driver Enumeration Policy 173