HP-UX Virtual Partitions Administrator's Guide (includes A.04.06 and A.05.04)
Table Of Contents
- HP-UX Virtual Partitions Administrator’s Guide
- Table of Contents
- About This Document
- 1 Introduction
- 2 How vPars and Its Components Work
- Partitioning Using vPars
- vPars Monitor and Database
- Boot Sequence
- Virtual Consoles
- Security
- EFI and Integrity Notes
- Integrity Differences Relative to PA-RISC
- Comparing vPars on PA-RISC and Integrity
- Comparing vPars Versions
- Resource Migration and Required States
- Transitioning from vPars A.03.xx to vPars A.04.xx/A.05.xx (CPU Syntax and Rules)
- 3 Planning Your System for Virtual Partitions
- Full ioscan Output of Non-Cellular System Named winona
- Full ioscan Output of Cellular (nPartitionable) System Named keira
- Planning, Installing, and Using vPars with an nPartitionable Server
- Planning Your Virtual Partitions
- Mixed HP-UX 11i v1/v2 vPars Environments in vPars A.04.05
- Mixed HP-UX 11i v2/v3 vPars Environments in vPars A.05.xx
- Mixed HP-UX 11i v1/v2/v3 vPars Environments in vPars A.05.03
- 4 Installing, Updating, or Removing vPars and Upgrading Servers with vPars
- Notes, Cautions, and Other Considerations Before You Update or Install vPars
- Bundle Names
- Setting Up the Ignite-UX Server
- Ignite-UX, the LAN, the LAN card, and vparboot -I
- Updating from vPars A.04.xx to A.05.xx
- Updating from vPars A.03.xx to Mixed HP-UX 11i v1/v2 vPars (A.03.05 and A.04.05) Environment
- Migrating from vPars A.03.xx to Mixed HP-UX 11i v1/v2/v3 vPars (A.03.05, A.04.02 or later, A.05.03)
- Updating from vPars A.04.xx to Mixed HP-UX 11i v2/v3 vPars (A.04.xx and A.05.xx) Environment
- Updating from vPars A.03.xx to A.05.xx
- Updating from vPars A.03.xx to A.04.xx
- Updating vPars A.03.xx to vPars A.03.05
- Updating from vPars (A.02.xx or A.03.xx) to A.03.xx
- Applying a vPars Sub-System Patch
- Upgrading Integrity Servers from the sx1000 to sx2000 Chipset
- Upgrading HP 9000 Servers from the sx1000 to sx2000 Chipset
- Upgrading Backplanes from PCI to PCI-X
- Updates Involving VPARSBASE
- Installing vPars with Ignite-UX on PA-RISC
- Installing vPars with Ignite-UX on Integrity
- Installing vPars with Software Distributor
- Removing the vPars Product
- 5 vPars Monitor and Shell Commands
- Notes on Examples in this Chapter
- Modes: Switching between nPars and vPars Modes (Integrity Only)
- EFI Boot Disk Paths, including Disk Mirrors, and vparefiutil (Integrity Only)
- vPars Monitor: Booting the vPars Monitor
- vPars Monitor: Accessing the vPars Monitor Prompt
- vPars Monitor: Using vPars Monitor Commands
- vPars Monitor: Using the vPars Monitor Commands from ISL or EFI
- Commands: vPars Manpages
- Commands: vPars Commands Logging
- Commands: Displaying vPars Monitor and Resource Information (vparstatus)
- Virtual Partition States
- vparstatus Output Examples
- vparstatus: Summary Information
- vparstatus: Verbose Information
- vparstatus: Available Resources
- vparstatus: CPU Information on vPars A.04/A.05
- vparstatus: Dual-Core CPUs
- vparstatus: Pending Migrating CPUs Operations
- vparstatus: Pending Migrating Memory Operations
- vparstatus: Base and Float Memory Amounts
- vparstatus: Pending nPartition Reboot for Reconfiguration
- vparstatus: vPars Monitor and Database Information
- Managing: Creating a Virtual Partition
- Managing: Removing a Virtual Partition
- Managing: Modifying Attributes of a Virtual Partition
- Booting a Virtual Partition
- Shutting Down or Rebooting a Virtual Partition
- Shutting Down or Rebooting the nPartition (Or Rebooting the vPars Monitor)
- Setboot and System-wide Stable Storage
- Using Primary and Alternate Boot Paths
- Autoboot
- Single-User Mode
- Other Boot Modes
- Resetting a Virtual Partition
- Using an Alternate Partition Database File
- Managing Resources With Only One Virtual Partition
- 6 CPU, Memory, and I/O Resources (A.05.xx)
- I/O: Topics
- I/O: Concepts and Functionality
- I/O: Adding or Deleting LBAs
- I/O: Allocation Notes
- Memory: Topics
- Memory: Concepts and Functionality
- Memory: Assigning (Adding) or Deleting by Size (ILM)
- Memory: Assigning (Adding) Or Deleting by Size (CLM)
- Memory: Assigning (Adding) Or Deleting by Address Range
- Memory: Available and Assigned Amounts
- Memory: Converting Base Memory to Float Memory
- Memory: Granularity Concepts
- Memory: Granularity Issues (Integrity and PA-RISC)
- Memory: Setting the Granularity Values (Integrity)
- Memory: Setting the Granularity Values (PA-RISC)
- Memory: Notes on vPars Syntax, Rules, and Output
- CPU: Topics
- CPU: Concepts and Functionality
- CPU: Specifying Min and Max Limits
- CPU: Adding and Deleting by Total
- CPU: Adding or Deleting by CLP (Cell Local Processor)
- CPU: Adding or Deleting by Hardware Path
- CPU: Notes on vPars Syntax, Rules, and Output
- CPU: Dual-Core Processors
- CPU: Hyperthreading ON/OFF (HT ON/OFF)
- CPUs: Managing I/O Interrupts
- CPU: CPU Monitor (Formerly Known As LPMC Monitor)
- Memory, CPU: Canceling Pending Operations
- 7 CPU, Memory, and I/O Resources (A.04.xx)
- I/O: Concepts
- I/O: Adding or Deleting LBAs
- I/O: Allocation Notes
- Memory: Concepts and Functionality
- Memory: Assigning by Size (ILM)
- Memory: Assigning by Size (CLM)
- Memory: Specifying Address Range
- Memory: Granularity Concepts
- Granularity Issues (Integrity and PA-RISC)
- Memory: Choosing a Granularity Value and Boot Time (Integrity)
- Memory: Setting the Granularity Values (Integrity)
- Memory: Setting the Granularity Values (PA-RISC)
- Memory: Allocation Notes
- CPU
- CPU: Boot Processor and Dynamic CPU Definitions
- CPU: Specifying Min and Max Limits
- CPU: Adding and Deleting by Total
- CPU: Adding or Deleting by CLP (Cell Local Processor)
- CPU: Adding or Deleting by Hardware Path
- CPU: Syntax, Rules, and Notes
- Managing I/O Interrupts
- CPU: Using iCAP (Instant Capacity on Demand) with vPars (vPars A.04.xx and iCAP B.07)
- CPU: Dual-Core Processors
- CPU: CPU Monitor (Formerly Known As LPMC Monitor)
- 8 CPU, Memory, and I/O Resources (A.03.xx)
- I/O: Concepts
- I/O: Adding or Deleting LBAs
- I/O: Allocation Notes
- Memory: Concepts and Functionality
- Memory: Assigning by Size (ILM)
- Memory: Specifying Address Range
- Memory: Allocation Concepts and Notes
- CPU
- CPU: Specifying Min and Max Limits
- CPU: Bound and Unbound
- CPU: Determining Whether to Use Bound or Unbound
- CPU: Determining When to Specify a Hardware Path for a Bound CPU
- CPU: Adding and Removing Bound CPUs
- CPU: Adding a CPU as a Bound CPU
- CPU: Removing a Bound CPU
- CPU: Adding, Removing, and Migrating Unbound CPUs
- CPU: Managing I/O Interrupts
- CPU: Dual-Core Processors
- CPU: CPU Monitor (Formerly Known As LPMC Monitor)
- 9 nPartition Operations
- Basic Conceptual Points on using vPars within nPartitions
- nPartition Information
- Setting Hyperthreading (HT ON/OFF) and cpuconfig Primer
- Rebooting and Reconfiguring Conceptual Points
- Reconfiguring the nPartition
- Putting an nPartition into an Inactive State and Other GSP Operations
- Configuring CLM for an nPartition
- 10 Crash Processing and Recovery
- Crash Processing
- Network and Tape Recovery
- Using make_net_recovery within a vPars Environment
- Using make_tape_recovery Outside of a vPars Environment
- Using make_tape_recovery and Dual-media Boot
- Using make_tape_recovery within a vPars Environment
- Expert Recovery
- 11 vPars Flexible Administrative Capability
- Synopsis
- Terms and Definitions
- Flexible Administrative Capability Commands
- monadmin
- vparadmin
- Persistence across vPars Monitor Reboots
- vPars Commands
- Example vPars Monitor Scenario (monadmin)
- Example HP-UX Shell Scenario (vparadmin)
- A Command Successfully Executed
- A Command Not Executed Due to the Flexible Administrative Capability Feature
- Adding a Virtual Partition to the Designated-admin Virtual Partition List
- Deleting a Virtual Partition to the Designated-admin Virtual Partition List
- Listing the Virtual Partitions in the Designated-admin Virtual Partition List
- Changing the Flexible Administrative Capability Password
- Determining whether Flexible Administrative Capability is ON or OFF
- 12 Virtual Partition Manager (A.03.xx)
- A LBA Hardware Path to Physical I/O Slot Correspondence (PA-RISC only)
- B Problem with Adding Unbound CPUs to a Virtual Partition (A.03.xx)
- C Calculating the Size of Kernels in Memory (PA-RISC only)
- D Memory Usage with vPars in nPartitions
- E Moving from a Standalone to vPars
- F Supported Configurations for Memory Migration
- Glossary
- Index

Deleting CPUs Summary
• You can delete any CPU, except the current boot processor, by specifying its hardware path.
• If you want to control which CPU is deleted (rather than leaving it up to the vPars Monitor),
use the same method—by CLP, by hardware path, or by count—on your deletion command
line that you used on your addition command line.
• The current boot processor can not be deleted from a virtual partition. (Use vparstatus
-v to determine the current boot processor.) You will need to shutdown the virtual partition
and delete the desired CPU.
Managing I/O Interrupts
This section describes information you need if you are managing I/O interrupts on a vPars-enabled
system. Note that migrating interrupts should only be done by advanced administrators for
performance tuning.
intctl Command
The intctl command is a HP-UX tool that allows you to manage I/O interrupts among active
CPUs.
For HP-UX 11i v2 and later, the software for intctl is part of the Core OS.
For more information, see the Interrupt Migration Product Note available at http://docs.hp.com
or the intctl(1M) manpage.
Notes
• At boot time of a virtual partition, interrupts are processed by all the CPUs in the virtual
partition.
• After boot, CPUs that are added to the virtual partition are not assigned to process I/O
interrupts. However, you can migrate I/O interrupts to any added CPU using intctl.
• After boot, CPUs that are deleted from a virtual partition no longer process I/O interrupts
for the partition. When a CPU is deleted from a virtual partition, if the deleted CPU has I/O
interrupts, the I/O interrupts are automatically and transparently reassigned to other active
CPUs in the partition.
NOTE: Repeatedly adding and deleting CPUs without a reboot of the target virtual partition
may cause an imbalance in the interrupt processing load across the CPUs of the virtual partition.
However, you can use intctl to rectify the imbalance if necessary.
CPU: Using iCAP (Instant Capacity on Demand) with vPars (vPars A.04.xx
and iCAP B.07)
iCAP CPUs are unlicensed CPUs. The unlicensed CPUs may be shown as available CPUs in the
vparstatus -A output. To use iCAP CPUs, you must first purchase them; then, you can activate
and assign them to a virtual partition.
For detailed information on using iCAP in vPars environment, including using earlier versions
of iCAP (formerly known as iCOD) with earlier versions of vPars, see the corresponding HP
Instant Capacity User’s Guide.
Purchasing Licenses for iCAP CPUs
To purchase licenses for any iCAP components, including iCAP CPUs, you must follow the
normal iCAP process as shown in the HP Instant Capacity User’s Guide. If you attempt to assign
an iCAP CPU before purchasing the license, you will get an iCAP authorization error.
Managing I/O Interrupts 237