SFM Release Notes for HP-UX 11i v3 September 2012 web release
Workaround: To reflect newly configured IP Addresses in SFM Indication, disable and enable
SFMProviderModule using the following commands
cimprovider -dm SFMProviderModule
cimprovider -em SFMProviderModule
• Problem: The firmware version of Management Processor firmware (MFW), given by
MPProvider and FirmwareRevisionProvider on HP Integrity rx2800 i2 server may be incorrect.
Description: The revision number (third field in':' separated version string) may be incorrect.
Workaround: Run the sysrev command from MP to get the correct MFW version
• Problem: The WBEM events do not get delivered to evweb.
Description: In an exceptional scenario, due to extreme stress condition, the database
component can get into a deadlock. In such cases, no events can be stored to database and
hence evweb cannot show any WBEM indication.
Workaround: Manually kill SFMProviderModule process and restart SFMProviderModule using
the following command:
cimprovider -em SFMProviderModule
• Problem: After OE install, SFM generates harmless warning messages in the install log file.
Description: The following messages are generated:
PGS04838: Warning: Class HP_CommonRecordLog already exists in the repository
PGS04838: Warning: Class HP_CommonLogRecord already exists in the repository
This message is written to the log when a module is registered to the class ahead of SFM. This
is a warning message which indicates that the class is already registered.
cron may not be running - call your system administrator
warning: commands will be executed using /usr/bin/sh
The message cron may not be running is logged if the cron daemon does not run during
the install. The warning commands will be executed using /usr/bin/sh occurs if
the default login shell is not defined POSIX shell /usr/bin/sh. This is a warning from cron
that the POSIX shell is used to execute commands in the crontab file. If the login shell is set to
/usr/bin/sh in the /etc/passwd file, this error is not logged.
Workaround: You can safely ignore both these warning messages.
• Problem: The second lan interface configured on a server is not accessible for web browsing.
Description: When a second lan interface was configured on a server using a private subnet
used only for cluster heartbeat traffic, the “Launch SMH” button got the second lan interface’s
address but was not accessible for web browsing.
Workaround: Disable the second lan, restart SFMProviderModule, and configure the second
lan card. After configuring, do not restart the server, Cimserver, and SFMProvider module.
In the case of a multi LAN environment configuration, do not restart any of the following:
◦ SFMProviderModule
◦ Cimserver
◦ Server
• Problem: The events and user defined subscriptions (created using Evweb) are lost when
diagnostic products are upgraded on a DRD cloned disk.
Description: Prior to September 2012 release version of the diagnostics product, the postgres
7.4.2 version was supported. However version 8.4.8 is shipped from September 2012 release.
Due to the missing data compatibility between PostgreSQL version 7.4.2 (prior to September
2012) and 8.4.8 (September 2012 release or later), when the diagnostics products are
System Fault Management C.07.09.02.03 release notes HP-UX 11i v3 September 2012 web release 11