SFM Release Notes for HP-UX 11i v3 March 2013
Table Of Contents

SFM is the default monitoring mode. However, you can switch to the OnlineDiag monitoring mode.
For information on how to switch to the OnlineDiag mode, see the SFM Administrator's Guide at
http://www.hp.com/go/hpux-diagnostics-docs
The diagnostic mode will be set to SFM mode by default on updating SFM. This overrides any
previous mode setting done manually on the system and needs to be restored. Verify the current
diagnostic mode before and after the update/installation of the WBEM Management Bundle.
NOTE: OnlineDiag monitoring mode is not supported on HP Integrity BL860c i2, BL870c
i2 & BL890c i2 Server Blades, rx2800 i2, HP Integrity Superdome 2, HP
Integrity BL860c i4, BL870c i4, BL890c i4 and rx2800 i4. Therefore, switching
between modes will not be available on these HP Integrity Servers.
The Event Monitoring Service (EMS) wrapper provider receives events generated by the EMS
hardware monitors. The following EMS hardware monitors are supported on HP 9000 servers
running the HP-UX 11i v3 operating system:
• LPMC (now CPU) (lpmc_em)
• Memory (dm_memory)
• Core HW (dm_core_hw)
• Chassis Code (dm_chassis)
• IPMI Forward Progress Log Monitor (fpl_em)
The following EMS hardware monitors are supported on HP Integrity servers running the HP-UX
11i v3 operating system:
• Corrected platform error monitor (cpe_em)
• IPMI forward progress log monitor (fpl_em)
• CMC monitor (cmc_em)
• Itanium core hardware monitor (ia64_corehw)
• Itanium memory monitor (memory_ia64)
NOTE: All of EMS hardware monitors are not supported by EMS wrapper provider included in
SFM product. For information on other providers like I/O and Storage, see HP WBEM providers
at http://www.hp.com/go/hpux-wbem-docs
Defect fixes
• QXCR1001236889
Problem: Group operational status of temperature sensors is not in sync with individual
operational status of sensors.
Resolution: This problem is fixed. The group operational status is updated whenever the
individual sensor status is updated.
• QXCR1001143295
Problem: The cprop is not displaying all Power Supply modules immediately after a system
reboot.
Resolution: This problem in inventory information is fixed.
• QXCR1001217840
Problem: The max/min values of parameters in DBConfig.xml are not hardcoded.
Resolution: This problem is fixed.
6