SFM Release Notes for HP-UX 11i v3 March 2011

QXCR1001046309
Unexpected observations are observed related to destination in EVWEB subscriptions
Problem: Multiple destinations encounters unexpected errors during EVWEB subscriptions
while using –r specifies multiple destination.
Resolution: This problem is fixed.
QXCR1001071600
In EVWEB add additional FRU properties for HP_DeviceIndication
Problem: In EVWEB, the following additional FRU properties of HP_DeviceIndication are
supported for MemoryIndicationProvider:
AdditionalHWPhysicalLocation[];
AdditionalHWSerialNumber[];
AdditionalHWPartNumber[];
AdditionalHWManufacturer[];
AdditionalHWFRUDetails[];
Resolution: This problem is fixed.
QXCR1001073935
CpuDiag fails to run on processors in pset1
Problem: CpuDiag healthtest fails on all processors in pset1 stating the following error: "System
call failed! For detailed information about cause and solution, see the man page. [mpct1(2),
errno=22]"
Resolution: This problem is fixed.
QXCR1001079348
Enclosure and blade pages were missing due to an extra character in SMH
Problem: Blade and enclosure pages were missing on the SMH when opened with Firefox
browser due to an extra character found in one of the property.
Resolution: This problem is fixed.
QXCR1001043856
Indictment does not happen correctly on HP Superdome 2 systems.
Problem: When an event with event number 100148 is generated on HP Superdome 2 systems,
the indictment does not happen correctly and the HealthState on HR repository does not reflect
the correct status.
Resolution: This problem is fixed.
QXCR1001041822
SFM consumes excessive memory in idle state on HP Superdome 2 systems.
Problem: Memory growth, observed in SFM provider module, is created after every 10 minutes
which has a stack memory of one MB.
Resolution: This problem is fixed.
QXCR1001045495
SFM's internal cache is being refreshed.
Problem: Whenever a client uses the internal SFM inventory, there is a refresh invoked for
processor and blade inventory on HP Superdome 2. An "Inventory Being Built" exception is
seen intermittently.
Resolution: This problem is fixed.
System Fault Management C.07.03.10.01 Release Notes HP-UX 11i v3 March 2011 7