SFM Release Notes for HP-UX 11i v3 August 2010
Systems that have upgraded to SFM C.07.00.07.01 (May 2010) or later.
Description: When SFM is upgraded from any version prior to C.07.00.04.06 (March 2010) release to C.07.01.06.01 (September 2010) version,
some systems that have previous events in the database, the cimprovagt process for SFMProviderModule may consume excessive amount of
memory or produce a core dump. The process list may display two cimprovagt process for SFMProviderModule. One of this process is orphan and
will not monitor hardware(s).
Workaround: Follow the steps given below before upgrading SFM to C.07.01.06.01 version.
Disable SFMProviderModule using the following command:
# cimprovider -dm SFMProviderModule
Problem: IPMI FRU calls fail when a blade with MMP is inserted into a different slot.
Description: On HP Integrity BL860c i2, BL870c i2 & BL890c i2 Server Blades system, when blades are moved across different slots in an
enclosure, the inventory shown by enumerating HP_Blade or the blade property page on HP SMH does not reflect the correct set of blades on the
system.
Workaround: This problem has the following two workarounds:
1. Use the Onboard Administrator to determine the total number of blades on the system.
2. Disable SFMProviderModule using the
cimprovider -dm SFMProviderModule command. Run mv /var/opt/sfm/data/sdrcache
/tmp/sdrcache
command to move the sdrcache file and enable SFMProviderModule cimprovider -em SFMProviderModule
Problem: CIM_AlertIndication.NetworkAddresses does not contain all assigned IP addresses.
Description: Indication delivered by SFM does not display all the IP addresses in NetworkAddresses property of CIM_AlertIndication class when
a new IP address is configured or an old IP address is changed at runtime.
Workaround: To reflect newly configured IP Addresses in SFM Indication, disable and enable SFMProviderModule using the following
commands
cimprovider -dm SFMProviderModule
cimprovider -em SFMProviderModule
Product Documentation
For more information on SFM, see the following documents at:
http://www.hp.com/go/hpux-diagnostics-docs
SFM Frequently Asked Questions (FAQs)
System Fault Management Administrator's Guide
SFM Release Notes
SFM Provider Data Sheets
SFM Tables of Versions
SFM Patch Descriptions
SFM Event Descriptions
Software and Documentation Availability in Native Languages
SFM software and documents are available only in the English language.
Product Structure
The SFM product, consisting of SFM providers and EVWEB, is installed as part of the SysFaultMgmt bundle.
Following are the commands you must use to obtain the bundle, product, sub-product, and the fileset information about the
SysFaultMgmt depot. The
generated output are examples from HP 9000 systems:
Bundle
$ swlist -s <SysFaultMgmt Depot Location>
SysFaultMgmt C.07.02.xx.yy HPUX System Fault Management
Product(s)
$ swlist -l product -s <SysFaultMgmt Depot Location>
SFM-CORE C.07.02.xx HPUX System Fault Management
SFMDB C.07.02.xx HP System Management Database (SFMDB)
Sub-product(s)
$ swlist -l subproduct -s <SysFaultMgmt Depot Location>
# SFM-CORE C.07.02.xx HPUX System Fault Management
SFM-CORE.ERROR-MGMT Error Management Technology
SFM-CORE.EVMCIM EVMCIM
SFM-CORE.EVWEB EVWEB
SFM-CORE.FMD-PROVIDER FMD-PROVIDER
SFM-CORE.GS GS
SFM-CORE.HS-PROVIDER HS-PROVIDER
SFM-CORE.SFM-HAS SFM-HAS
SFM-CORE.SFM-PROPPAGE SFM PROPERTY PAGE
SFM-CORE.SFM-PROVIDER SFM-PROVIDER
SFMDB C.07.02.xx HP System Management Database (SFMDB)
Fileset(s)
$ swlist -l fileset -s <SysFaultMgmt Depot Location>
# SFM-CORE C.07.02.xx HPUX System Fault Management