SFM Release Notes for HP-UX 11i v2 August 2011

Providers may fail with the generation of the CIM_ERR_FAILED status code. Also, a message
is displayed on the client system that states " Inventory information is being built currently.
Please try after some time" . However, on subsequent requests, the SFM hardware inventory
providers respond with requested information instantaneously.
Hardware inventory providers are not supported on HP Virtual Machines. For indication
providers, only FPL and ia64_corehw indications are generated on HPVM guests.
The errors processed by the SFMIndicationProvider cannot be sent to the EMS monitors when
you switch from the SFMIndicationProvider to EMS monitors.
Known Problems and Workarounds
Problem: CIM_AlertIndication.NetworkAddresses does not contain all assigned IP addresses.
Description: Indication delivered by SFM does not display all the IP addresses in
NetworkAddresses property of CIM_AlertIndication class when a new IP address is configured
or an old IP address is changed at runtime.
Workaround: To reflect newly configured IP Addresses in SFM Indication, disable and enable
SFMProviderModule using the following commands:
cimprovider -dm SFMProviderModule
cimprovider -em SFMProviderModule
Problem: OSELReader reading from wrong file causes missing events
Description: This problem is seen when OnlineDiag product is upgraded from any version
prior to B.11.23.13.02 to B.11.23.13.02 or later version. Creation of duplicate OSEL files
causes this issue wherein few events could get missed.
Caution: Before upgrading OnlineDiag product from any version to B.11.23.13.02 or later
version, perform the following the steps:
# cp /opt/sfm/conf/fm_diaglogd_cfg.bin /var/opt/sfm/conf/
# ls l /var/opt/sfm/conf/fm_diaglogd_cfg.bin
Workaround: If the steps mentioned in Caution were not followed prior to upgrade of
OnlineDiag product from any version to B.11.23.13.02 or later version, then perform the
following steps:
# cimprovider dm SFMProviderModule
# strings /var/opt/sfm/data/last_read_state.sav
Output: This will give the name of the OSEL file to be deleted.
# rm <give the name of the osel file got from the above output>
# rm /var/opt/sfm/data/last_read_state.sav
# cimprovider em SFMProviderModule
Product documentation
For more information on SFM, see the following documents at:
www.hp.com/go/hpux-diagnostics-sfm-docs
Frequently Asked Questions (FAQs)
Administrator's and User's Guide for SFM HP-UX 11i v3
SFM Provider Data Sheets
SFM Tables of Versions
8 Contents