HP-UX WBEM System Fault Management (SFM) Administrator Guide (September 2013)
Table 2 Instance providers (continued)
DescriptionInstance provider
The ComputerSystem Chassis provider provides the following details related
to the logical server:
• VirtualSerialNumber
• VirtualUUID
These values are retained when an OS instance is moved to another server.
The Consolidated Status provider provides the overall health status of various
subsystems of the managed node. The overall health status is consolidated
from the health status of individual status providers registered with WBEM.
Consolidated Status provider
The SysFaultMgmt (System Fault Management) (SFM) providers that
contribute to the overall health status are:
Blade
CPU
Memory
Environmental
Firmware Revision
Management Processor
Enclosure
Temperature Sensor
Indication providers
SysFaultMgmt (System Fault Management) (SFM) includes four indication providers, the EMS
Wrapper provider, the Event Manager Common Information Model (EVM CIM) provider,
SFMIndicationProvider and MCA indication provider. Table 3 describes the SysFaultMgmt (System
Fault Management) (SFM) indication providers.
Table 3 Indication providers
DescriptionIndication provider
The EMS Wrapper provider does the following:EMSWrapperProvider
1. Converts hardware events generated by the EMS Hardware
Monitors into WBEM indications.
2. Reports the WBEM indications to the CIMOM. Using a
WBEM-based management application, such as HP SIM, you
can subscribe to and receive Event Monitoring Service (EMS)
events generated on a remote system. On the system on which
SysFaultMgmt (System Fault Management) (SFM) is installed,
you can use an SysFaultMgmt (System Fault Management)
(SFM) tool, called EVWEB, to view and administer events
through the HP SMH interface.
The following EMS Hardware Monitors are supported on HP 9000
servers running the HP-UX 11i v3 operating system:
• LPMC (now CPU) (lpmc_em)
• Memory (dm_memory)
• Core HW (dm_core_hw)
• Chassis Code (dm_chassis)
• Integrity Core Hardware Monitor(ia64_corehw)
• IPMI Forward Progress Log Monitor (fpl_em)
The following EMS Hardware Monitors are supported on HP
Integrity® servers running the HP-UX 11i v3 operating system:
• Corrected Platform Error Monitor (cpe_em)
• IPMI Forward Progress Log Monitor (fpl_em)
Components of SysFaultMgmt (System Fault Management) (SFM) 13