HP-UX WBEM System Fault Management (SFM) Administrator Guide (September 2013)
Cell Board instances
This section describes the Cell Board instances.
Figure 35 Sample Cell Board property page
Table 49 (page 121) describes the fields and enables you to interpret the values displayed in
Figure 35 (page 121).
Table 49 Description of the Cabinet Fields and Values
DescriptionFields and Values
Displays string for the firmware revision number, consisting of the major number separated
from the minor number by a period.
Firmware Version
Indicates the status of the component. The status values are Unknown(0), Other(1),
Powered Off(2), Powering On(3), Inactive(4), and Active(5).
Status
Defines the value to True, if the I/O chassis connected to the cell has a core I/O card. False,
if the cell is not connected to an I/O chassis or the I/O chassis does not have a core I/O
card.
Core IO
Displays the I/O Chassis ID of the chassis to which the cell is connected. The property is not
present if ConnectedToIOChassis is false.
IO Chassis Connected
Cell Board instances 121