Table 5 EMS, WBEM and Evweb Events Severity values (continued)
Evweb SeverityWBEM SeverityEMS Severity
7 Critical6 Critical4 Serious
7 Critical7 Fatal/Non-recoverable5 Critical
NOTE: Perceived Severities in Syslog is same as WBEM severities.
In the SFM mode although the SFMIndicationProvider is generating the events, the name of the
provider displayed in the event details is one of the following providers mentioned under Provider
in Table 4–2, depending on the device to which the event is related. Table 6 (page 40) maps the
EMS Hardware Monitors and the corresponding WBEM providers.
Table 6 Representation of Monitors
IA NGIS providers
2
IA Legacy Provider
1
PA-RISC ProviderMonitor
CPU_IndicationProviderIACMC_IndicationProviderIACMC_IndicationProviderIAcmc_em
PCIeIndicationProvider
4
CPE_IndicationProviderIA
3
CPE_IndicationProviderIAcpe_em
CoreHardwareIndicationProviderdm_core_hw
ChassisIndicationProviderChassisIndicationProviderChassisIndicationProviderdm_chassis
DiskIndicationProvider
5
DiskIndicationProvider
5
DiskIndicationProviderdisk_em
FPL_IndicationProviderFPL_IndicationProviderFPL_IndicationProviderfpl_em
SEL02_IndicationProviderSEL02_IndicationProviderSEL02_IndicationProvideria64_corehw
LPMC_IndicationProviderlpmc_em
MemoryIndicationProviderMemoryIndicationProviderMemoryIndicationProvidermemory_ia64
1
Legacy : HP Integrity platforms supporting processors prior Intel 9300.
2
NGIS : HP Integrity platfroms supporting Intel 9300 processors
3
Supported on HP Integrity BL860c i2, BL870c i2 & BL890c i2 Server Blades and rx2800 i2
4
This provider is supported only on HP Superdome 2 servers.
5
This provider is not shipped as part of SFM from March 2009 release.
Table 7 compares the EMS Hardware Monitors properties with the equivalent EMS Wrapper
Provider / Native Indication Provider properties.
Table 7 Property Representation
EMS Wrapper Provider / Native Indication ProviderEMS Hardware Monitors
EventTimeEvent Time
PerceivedSeveritySeverity
EventIDEvent
SystemNameSystem
SummarySummary
DescriptionDescription of Error
ProbableCauseDescription and
RecommendedAction (these two are separate fields)
Probable Cause/ Recommended Action
SystemSerialNumberSystem Serial Number
HWManufacturerInquiryVendorID
40 Administering Indications and Instances Using HP SIM