Administrator's and User's Guide for SFM HP-UX 11i v1 April 2006
Troubleshooting SFM
Troubleshooting Indication Providers
Chapter 5 113
Troubleshooting Indication Providers
This section describes the techniques for troubleshooting the EMS
Wrapper Provider.
Problem
Indications corresponding to events generated by the Event Monitoring
Service (EMS) monitors, are not logged in the Events List.
Cause 1
CIMOM is not running.
Solution
Enter the following command at the HP-UX prompt:
# ps -eaf | grep cimserver
If the name cimserver is displayed in the output, the CIMOM is running
properly. If cimserver is not displayed in the output, stop the CIMOM
by entering the following command at the HP-UX prompt:
# cimserver -s
To restart the CIMOM, enter the following command at the HP-UX
prompt:
# cimserver
Cause 2
The provider module is not registered.
Solution
To check whether the provider module is registered, and to check its
status, enter the following command at the HP-UX prompt:
# cimprovider -l -s
MODULE STATUS
SFMProviderModule OK
HPUX_ControlProviderModule OK
ErrorMetadataProviderModule OK
EMArchiveConsumerModule OK
FMDModule OK