HP-UX System Administrator's Guide: Configuration Management

Module pm_acct
Current Value 4 [Default]
Value at Next Boot 4 [Default]
Value at Last Boot 4
Default Value 4
Constraints acctresume >= -100
acctresume <= 101
acctresume > acctsuspend
Can Change At Next Boot Only
Tunable maxuprc
Description Maximum number of processes for each non-root user
Module pm_proc
Current Value 256 [Default]
Value at Next Boot 256 [Default]
Value at Last Boot 256
Default Value 256
Constraints maxuprc >= 3
maxuprc <= nproc - 5
Can Change Immediately or at Next Boot
Tunable nproc
Description Maximum number of processes on the system
Module pm_proc
Current Value 4200 [Default]
Value at Next Boot 4200 [Default]
Value at Last Boot 4200
Default Value 4200
Constraints nproc >= 100
nproc <= 131072
nproc >= semmnu + 4
nproc >= maxuprc + 5
nproc <= nkthread - 100
Can Change Immediately or at Next Boot
With the -P Option The -P option, which is designed for use by scripts or programs,
gives you complete control over what information is printed. For more information,
see “Parsing Command Output” (page 196) or the kconfig(5) manpage.
The special keyword ALL displays all the possible categories. Compare with the -v
option.
# kctune -P ALL nproc
name nproc
module pm_proc
desc Maximum number of processes on the system
defvalue 4200
bootvalue 4200
current 4200
next_boot 4200
expr Default
next_expr Default
min 100
max 131072
dynamic y
canauto n
default y
auto_default n
next_default y
signed n
flags 0x6c3
constraint nproc >= 100
constraint nproc <= 131072
172 Configuring the Kernel