Software Distributor Release Notes HP-UX 11i v2, HP-UX 11i v3 HP Part Number: 766151-001 Published: March 2014 Edition: 1
Legal Notices © Copyright 2012, 2014 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license. The information contained herein is subject to change without notice.
Contents HP secure development lifecycle......................................................................4 Issues fixed..............................................................................................................................5 2014..................................................................................................................................5 March 2014 Release........................................................................................................
HP secure development lifecycle Starting with HP-UX 11i v3 March 2013 update release, HP secure development lifecycle provides the ability to authenticate HP-UX software. Software delivered through this release has been digitally signed using HP's private key. You can now verify the authenticity of the software before installing the products, delivered through this release. To verify the software signatures in signed depot, the following products must be installed on your system: • B.11.31.
This document provides information about installation requirements, the issues resolved, and known limitations of Software Distributor in HP-UX 11i v2 and HP-UX 11i v3 releases. Issues fixed This section lists the issues that have been resolved in a release, along with the SW-DIST fileset revision numbers. 2014 March 2014 Release 11.31 SW-DIST fileset revision B.11.31.1403.401 The whatstring: SD-UX/B.11.31.00.234, UDL_11.31_Mar14OEUR__IC401 You can download SD-UX version B.11.31.1403.401 from the web.
Table 3 Issues resolved in February 2013 Release QXCR1001239651 This enhancement supports signature verification of signed depots for the -x verify_signatures=true and-x verify_signatures_only=true options. QXCR1001235282 This fix addresses the issue in the Multi Network Interface Card (NIC) systems, where the analysis was passed and execution was failing. QXCR1001207711 This fix allows swinstall to support up to 124 keywords per session per CD part number. 2012 September 2012 September 2012 Release 11.
2011 September 2011 September 2011 Release 11.31 SW-DIST fileset revision B.11.31.1109.366 The whatstring: SD-UX/B.11.31.00.214, UDL_11.31_Sep11OEUR_IC366 You can download SD-UX version B.11.31.1109.366 from the web. For more information, visit http://www.hp.com/ go/sd Table 6 Issues resolved in September 2011 Web Release QXCR1001113608 This fix resolves the incorrect message catalog issue for Japanese and Korean locales which resulted in ^M characters to appear in the log files.
The whatstring: SD-UX/B.11.31.00.204, UDL_11.31_Sep10OEUR_IC352 This release, B.11.23.1009.352 and B.11.31.1009.352, can be downloaded from the web. For more information, see http://www.hp.com/go/sd Table 8 Defects fixed in September 2009 Web Release Defect ID Description QXCR1000578749 SD will not allow invisible characters in psf. QXCR1000937726 The time stamp of /usr/bin/ccwas updated after running swinstall. This was because the Upgrade product was installed on the machine.
Table 9 Defects fixed in March 2010 Web Release (continued) QXCR1000941503 With this fix, a depot existing only on the active system can be accessed from the DRD clone too. QXCR1000948434 With this fix, when swpackage and swmodify are invoked with -C option, the sessions file is stored only at the location specified with -C and not at the default location. Without the -C option, it is stored only at the default location.
Table 10 Defects fixed in September 2009 Web Release Defect ID Description QXCR1000766167 This fix ensures that a depot which is already empty can be removed using swremove with the "remove_empty_depot" option set to true. QXCR1000913668 The SD push controller (swcopy or swinstall) was using local hostname rather than fully qualified local hostname in the RPC call.
Table 11 Defects fixed in March 2009 Fixes Defect ID Description QXCR1000473250 The swinstall command has been changed to throw a WARNING message instead of an ERROR message when an installation of a lower version of a component upon a higher version on a system without "allow_downdate=true" option is attempted. The customer expects the message to be changed from ERROR to WARNING.
Table 12 Defects fixed in September 2008 release (continued) Defect ID Description tag name will be displayed in the swpackage log, even if they are longer than 16 characters. 12 QXCR1000532455: (JAGaf11611) Message changed from "x filesets were determined to be skipped in the analysis phase." to "x software objects were determined to be skipped in the analysis phase.
March 2008 March 2008 Web Release 11.23 SW-DIST fileset revision B.11.23.0803.318 11.31 SW-DIST fileset revision B.11.31.0803.318 The whatstring: SD-UX/B.11.31.00.172, UDL_11.31_Mar08OEUR_IC318_web This release, B.11.23.0803.318 and B.11.31.0803.318, can be downloaded from the web. For more information, see http://www.hp.com/go/sd/ Table 13 Defects fixed in March 2008 Defect ID Description QXCR1000559362/JAGaf91103 Problem with swagentd.
Table 14 Defects fixed in December 2007 (continued) Defect ID Description says hard links across filesets are not supported, and each file will be recorded as a regular file. The swpackage command has been fixed to not issue that warning, but otherwise to not change behavior. JAGag29971 The swinstall command issues a confusing message when the patch_match_target feature selects nothing and fails. The message is improved to list the potential reasons why nothing is selected.
Table 15 Defects fixed in September 2007 release Defect ID Description JAGag29254 A swapon() call may fail with errno 22 during swinstall or update-ux. The swagent program is fixed to prevent that swapon() failure. JAGag30553 A new option, autoselect_minimum_dependencies, has been added to control the selection of the first left-most dependency in a list of OR'd dependencies that satisfies a requisite.
Table 15 Defects fixed in September 2007 release (continued) Defect ID Description during the most recent packaging of the product residing on the source depot or during the current packaging of the product defined in the source psf. June 2007 June 2007 Web Release SW-DIST fileset revision B.11.23.0706.063 The whatstring: SD-UX/B.11.31.00.156, UDL_11.23_Jun07OEUR_IC063 This release, B.11.23.0706.063, can be downloaded from the web. For more information, see http://www.hp.
Table 16 Defects fixed in June 2007 release (continued) Defect ID Description JAGag28202 The temporary ioscan_out file created by control_utils function cu_hw_scan is not always removed at the end of the swinstall session. This release of SD is fixed to ensure ioscan_out is always removed at end of swinstall session. JAGag33786 SD is fixed to not issue "RPC exception" messages when they are due to inability to connect to a swagentd process.
Table 17 Defects fixed in December 2006 release (continued) Defect ID Description JAGag07018 The CIFS file system is now supported. The CIFS file system is treated as CDROM/DVD media so read-only is the only type of access available. JAGag08008 When a product specification is used for a bundle content and it contains the fileset architecture (fa=), the product's filesets were not listed when swlist was used to list the bundle's filesets.
Table 17 Defects fixed in December 2006 release (continued) Defect ID Description JAGag21177 swinstall and swremove man pages did not document the -x run_scripts option. This option is now documented. JAGag22312 Problem with gzip, swinstall, and swcopy. September 2006 HP-UX 11i v2 September 2006 Update Release SW-DIST fileset revision B.11.23.0609.052 The whatstring: SD-UX/B.11.31.00.132, UDL_11.23_Sep06OEUR_IC052 This release, B.11.23.0609.052, can be downloaded from the web.
Table 19 Defects fixed in June 2006 release (continued) Defect ID Description JAGaf90593 Problem with swcopy, swinstall, swask, swlist. JAGaf91668 The interactive user interface was modified so that control is automatically returned to update-ux (or ignite-ux) after the installation phase completes, regardless of whether or not any "is_reboot=true" filesets have been installed in that session.
Table 20 HP-UX 11i v2 March 2006 Fixes (continued) Defect ID Description JAGaf80703 In some circumstances, a defect in SD's dependency resolution module causes it to incorrectly calculate dependencies for software that declares product-level corequisites or prerequisites. This ultimately results in dependency errors during the analysis phase of swremove sessions.
Table 21 HP-UX 11i v2 December 2005 Fixes (continued) Defect ID 22 Description JAGaf63449 Fixed a memory leak in swinstall and swcopy that caused their process sizes to increase substantially while processing certain combinations of patch or patch bundle selections. The problem was most apparent with source depots containing high numbers of densely interdependent and superseded patch filesets.
May 2005 Table 22 HP-UX 11i v2 May 2005 Fixes Defect ID Description JAGae59730 Certain messages were not structured well for translating into other languages. JAGaf10364 In an interactive swinstall or swcopy session, if the analysis phase fails because all selected filesets were skipped or excluded, and if some of those filesets were excluded in order to avoid creating a split patch (i.e.
Table 22 HP-UX 11i v2 May 2005 Fixes (continued) Defect ID JAGaf45569 Description If a dependency is declared on a product instead of a fileset, swinstall may not correctly resolve the dependency if the product is compatible but contains incompatible filesets. (Note, however, that HP-UX packaging policy only allows dependencies on filesets).
Table 23 HP-UX 11i v2 September 2004 Fixes (continued) Defect ID Description or install to complete successfully. This fixes swinstall to not issue this message and to not unselect OS- Core.CORE2-KRN. JAGaf05956 In the swremove man page an example of how to remove all software from a depot now shows a backslash before the asterisk in the swremove command line. Previously, the example did not show a backslash before the asterisk.
Table 23 HP-UX 11i v2 September 2004 Fixes (continued) Defect ID Description JAGaf27207 use of 'get_os_rev' in control scripts modifies IFS. Some control scripts may not work correctly when IFS is modified. JAGaf27275 the "patch_newconfig_rollcheck" documentation said that it is to be used in a preremove script. It is actually to be used in a checkremove script.
Table 24 HP-UX 11i v2 March 2004 Fixes (continued) JAGae96976 swlist @ syntax fails if the target is a serial depot. JAGae99511 If a system makes use of RPC_SUPPORTED_NETADDRS, they would be unset by S120swconfig, and later startup scripts (eg ovstart) would cause errors. JAGaf02256 Swverify incorrectly shows a missing .o file in a depot created using the package_in_place features of swpackage. The .o is actually not missing, and swinstall for swcopy from the package_in_place work correctly.
Corrective Action: A fix in the 2Gb/4Gb drivers has been released. The following steps will resolve the issue: 1. Go to www.hp.com 2. Click Software & Driver Downloads. 3. In the white text box, type the name of the I/O card, such as A6826A. 4. Click the >> button. 5. Click the Cross Operating System button. 6. Look for EFI 1.49 for adapters A6826A, A9782A, A9784A, and AB465A. Look for EFI 1.05 for adapters AB378A and AB379A.
1. 2. • Attach loop back hoods to all of the unconnected HBA ports. The loop back hoods will cause the unconnected HBA ports to come online in a private loop topology. Install the product bundle, mtIOScan, that enables boot time kernel threads. This will reduce the overall boot delay due to unconnected ports to 21 seconds. This product can be obtained from www.software.hp.
Requirements for Boot Support: AD193A/AD194A, 403619–B21, AB378A, AB378B, AB379A, AB379B. A6826A. A9782A, A9784A, AB465A To boot through the fibre channel ports on these adapters, HP recommends that you update the EFI driver and onboard firmware to the latest version. The following table lists the recommended EFI and firmware versions at the release of FibrChanl-01 (fcd) driver, version B.11.23.
• A9784A PCI-X 2Gb Fibre Channel and 1000Base-T (Copper) Gigabit Ethernet Combination Card • AB465A PCI-X Dual Port 2Gb Fibre Channel and Dual Port 1000Base-T Gigabit Ethernet Combination Card Related information The latest documentation for the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 is available on the BSC website at www.hp.com/go/hpux-iocards-docs.