Software Distributor Requirements, Issues Fixed, and Workarounds HP-UX 11i v2, HP-UX 11i v3

Table 7 Defects fixed in September 2009 Web Release (continued)
swinstall(1) man page which says that if SW_INITIAL_INSTALL is set to any value during
a cold-install. This is not correct as Ignite-UX sets it to '0' when it is ready to build a kernel.
QXCR1000969551
The decription of SW_INITIAL_INSTALL has been changed to : This variable is normally
unset. If it is set to 1, the swinstall session is being run as the back end of an initial system
software installation ("cold" install). If it is unset or set to any other QXCR1000969551
value, then it is not a cold-install session.
This fix introduces a new option return_warning_exitcode. With this option any SD
controller commands will return 2 when there are any warnings but no errors during SD
controller operations. It is applicable only for single targets.
QXCR1000972301
With this fix, when any of the GUI of swinstall, swremove and swcopy command's
help dialog box is opened, the “Missing Graphic no longer appears. The note icon "i" is
seen.
QXCR1000985995
Utf8 locales will be supported in SD with this fix.QXCR1000986478
This fix addresses a potential hang with 1003 version of SD, during a DRD update.QXCR1000998317
There is a problem in swask(1) command.QXCR1001023437
With this fix the machine will be rebooted after installing a product having normal fileset
whose control script returns 12 as exit code.
QXCR1000885370
The sort algorithm in tlfileset.sh in the Upgrade product results in poor performance
of swinstall. Since the Upgrade product is obsoleted, this issue cannot be fixed and is
documented as a known issue in Known Problems and Limitations.
QXCR1000584047
March 2010
March 2010 Web Release
11.23 SW-DIST fileset revision B.11.23.1003.346
11.31 SW-DIST fileset revision B.11.31.1003.346
The whatstring: SD-UX/B.11.31.00.194, UDL_11.31_Mar10OEUR_IC346
This release, B.11.11.1003.346, B.11.23.1003.346 and B.11.31.1003.346, can be downloaded from the web.
For more information, see http://www.hp.com/go/sd
Table 8 Defects fixed in March 2010 Web Release
DescriptionDefect ID
When multiple filesets supersede the same fileset, a WARNING is issued that the conflicting
superseding filesets will not be used. However, their names/specifications is not displayed.
This defect is aimed at fixing this problem by displaying the conflicting fileset names.QXCR1000766167
When swinstall is run in the preview mode for selections including at least one reboot fileset
and autoreboot=false, then swinstall will now print the note saying "-x autoreboot" should be
true. This wasn't printed earlier.QXCR1000822070
With this fix, a depot existing only on the active system can be accessed from the DRD clone
too.QXCR1000941503
With this fix, when swpackage and swmodify are invoked with -C option, the sessions file is
stored only at the location specified with -C and not at the default location. Without the -C
option, it is stored only at the default location.QXCR1000948434
Removal of base product in supersession chain results in top most supersession patch left and
intermediate patches removal. Fix will prevent removal of intermediate patches in supersession
chain.QXCR1000861380
swinstall -p exits with SUCCESS status even though one of the selection not exists on depot.
swinstall is returning with SUCCESS in selection phase. A new option enforce_selections isQXCR1000593453
Issues fixed 7