Software Distributor Requirements, Issues Fixed, and Workarounds HP-UX 11i v2, HP-UX 11i v3

2012
September 2012
September 2012 Release
11.31 SW-DIST fileset revision B.11.31.1209.382
The whatstring: SD-UX/B.11.31.00.224, UDL_11.31_Sep12OEUR_IC382
You can download SD-UX version B.11.31.1209.382 from the web. For more information, visit http://www.hp.com/
go/sd
Table 3 Issues resolved in September 2012 Release
This fix avoids the failure of swpackage command when the session accesses file system >1TBQXCR1001181953
This fix addresses the scenario where swinstall fails in DRD environment if a dependent fileset is in
installed state and not present in the source depot of the fileset being installed. This can happen if
the two filesets are installed in multiple drd runcmd swinstall sessions.
QXCR1001186733
March 2012
March 2012 Release
11.31 SW-DIST fileset revision B.11.31.1203.373
The whatstring: SD-UX/B.11.31.00.219, UDL_11.31_Mar12OEUR_IC373
You can download SD-UX version B.11.31.1203.373 from the web. For more information, visit http://www.hp.com/
go/sd
Table 4 Issues resolved in March 2012 Release
This enhancement provides a new -x option srp_parallel. This option is only supported
in an HP-UX Containers (SRP) enabled system. It enables the parallel
installation/removal/configuration mode on containers.QXCR1001116243
This fix provides a new -x option softreboot to enable the softreboot feature for swinstall
and swremove.
QXCR1001154874
This enhancement provides a variable SW_ALLOW_LOCAL_SRP_OPS, which allows
swinstall, swremove, and swconfig to run on a system container.
QXCR1001095585
This enhancement adds debug logs identifying the corrupt fileset if the “Internal Error 202 in
function IC_TargetSoftwareGet” error is encountered. The SDU_DEBUG environment variable
must be set to 2 or more for the fileset information to be logged.QXCR1001130099
This fix displays a message about the roll-back save area as a NOTE instead of WARNING
when a patch is reinstalled.QXCR1001134864
2011
September 2011
September 2011 Release
11.31 SW-DIST fileset revision B.11.31.1109.366
The whatstring: SD-UX/B.11.31.00.214, UDL_11.31_Sep11OEUR_IC366
You can download SD-UX version B.11.31.1109.366 from the web. For more information, visit http://www.hp.com/
go/sd
Issues fixed 5