Software Distributor defects fixed in HP-UX 11i v1, v2 and v3

1. Attach loop back hoods to all of the unconnected HBA ports. The loop back hoods will
cause the unconnected HBA ports to come online in a private loop topology.
2. Install the product bundle, mtIOScan, that enables boot time kernel threads. This will
reduce the overall boot delay due to unconnected ports to 21 seconds. This product can
be obtained from www.software.hp.com
swlist Does Not Indicate the Mezzanine HBAs
swlist does not indicate the Mezzanine HBAs, and cannot be added onto because of string
size limitation.
Corrective Action: Refer to Hardware Requirements later in this document for more
information.
The time stamp of "/usr/bin/cc" was updated after running swinstall
The time stamp of /usr/bin/cc" was updated after running swinstall command when the
machine had the “Upgrade” product already installed on it.
This problem is due to the /opt/upgrade/bin/tlfileset.sh script, which does not
update the transition link database even if a product having a transition link is removed.
This causes incorrect link state for /usr/bin/cc and the timestamp of /usr/bin/cc to
change whenever swinstall command or tlinstall script is run.
Corrective Action: Remove “Upgrade” product using swremove upgrade. Upgrade product
is only for the customers migrating from HP-UX 9.X or 10.X to 11.X. This product is now
obsolete and unsupported.
swinstall has a poor performance if the machine has Upgrade product installed on it
This problem is due to the sort algorithm in tlfileset.sh script, which is a part of the
“Upgrade” product.
Corrective Action: "Upgrade" product is now obsolete and unsupported, hence this problem
cannot be fixed. “Upgrade” product is only for the customers migrating from HP-UX 9.X /
10.X to 11.X.
Compatibility and Installation Requirements
This section describes the compatibility information and installation requirements for this release.
For specific installation instructions, refer to the installation guide specific to your to your
FibreChannel card.
Operating System and Version Compatibility
The following software (or later versions) must be installed before installing the FibrChanl-01
(fcd) driver, version B.11.23.0903 into a system:
FibrChanl-00 (td) version B.11.23.0807 or later (for HP-UX 11i v2 Update 3)
Product number B6191AAE, OnlineDiag bundle version B.11.23.03.xx, release in September
2004 (HWE0409)
PHKL_33827 patch or later for HP-UX 11i v2 (needed for fcmsutil (1M) support for
options set_int_delay and get_int_delay)
PHKL_36143 patch (needed for fcmsutil(1M) support for option sfp supported by 4Gb
Fibre Channel HBAs)
PHKL_31500 patch or later (needed for HP-UX 11i v2)
PHKL_31226 patch (only needed if OLAR functionality is required; applies to all cards that
have a bridge, including A9782A, A9784A, and AB465A)
PHKL_34851 (needed for HP-UX 11i v2)
Driver bundles can be downloaded from the HP Software Depot at: http://www.software.hp.com
Patches are available from either: http://www.software.hp.com or http://itresourcecenter.hp.com