HP-UX SNAplus2 R7 NOF Programmer's Guide
NOF API Verbs
QUERY_DOWNSTREAM_LU
Number of normal flow data bytes received.
sidh
Session ID high byte. (In the upstream PLU-SLU session statistics for an LU served by PU concentration,
this parameter is reserved.)
sidl
Session ID low byte. (In the upstream PLU-SLU session statistics for an LU served by PU concentration,
this parameter is reserved.)
odai
Origin Destination Assignor Indicator. When bringing up a session, the sender of the BIND sets this field
to zero if the local node contains the primary link station, and sets it to one if the BIND sender is the node
containing the secondary link station. (In the upstream PLU-SLU session statistics for an LU served by PU
concentration, this parameter is reserved.)
ls_name
Link station name associated with statistics. This is an 8-byte ASCII character string, right-padded with
spaces if the name is shorter than 8 characters. (In the upstream PLU-SLU session statistics for an LU served
by PU concentration, this parameter is reserved.)
pacing_type
The type of receive pacing in use on this session. Possible values are:
AP_NONE
AP_PACING_FIXED
downstream_lu_detail.det_data.host_lu_name
Name of the host LU to which the downstream LU is mapped, or to which it was mapped when the
PLU-SLU session was last active. This parameter value may differ from
def_data.host_lu_name because
def_data.host_lu_name can be the name of a host LU pool.
If the downstream LU is used to communicate with a SNAplus2 Primary RUI application instead of a host,
this field is set to the string #PRIRUI# in EBCDIC.
downstream_lu_detail.det_data.host_pu_name
Name of the host PU to which the downstream LU is mapped, or to which it was mapped when the PLU-SLU
session was last active.
downstream_lu_detail.def_data.description
A null-terminated text string describing the downstream LU, as specified in the definition of the downstream
LU. For a DLUR-supported LU, this parameter is reserved.
downstream_lu_detail.def_data.nau_address
Network accessible unit address of the downstream LU.
downstream_lu_detail.def_data.dspu_name
Name of the downstream PU associated with this LU (as specified on the DEFINE_LS verb). This is an
8-byte type-A EBCDIC string (starting with a letter), padded on the right with EBCDIC spaces if the name
is shorter than 8 characters.
downstream_lu_detail.def_data.host_lu_name
Name of the host LU or host LU pool that the downstream LU uses. This is an 8-byte EBCDIC string,
padded on the right with EBCDIC spaces if the name is shorter than 8 characters.
If the downstream LU is used to communicate with a SNAplus2 Primary RUI application instead of a host,
this field is set to the string #PRIRUI# in EBCDIC.
This field is reserved for DLUR-served downstream LUs.
439