HP-UX SNAplus2 R7 LUA Programmer's Guide
SLI Verbs
SLI_BID
lua_sec_rc
LUA_INVALID_PROCESS
The operating system process that issued this verb was not the same process that issued the SLI_OPEN
verb for this session. Only the process that started a session can issue verbs on that session.
The following return codes indicate that the verb did not complete successfully for other reasons:
lua_prim_rc
LUA_COMM_SUBSYSTEM_ABENDED
A required SNAplus2 software component (such as the node) has terminated. Contact your System
Administrator if necessary.
lua_prim_rc
LUA_SESSION_FAILURE
The LUA session has failed. To restart it, the application can reissue SLI_OPEN.
lua_sec_rc
Possible values are:
LUA_LU_COMPONENT_DISCONNECTED
This return code indicates that the LUA session has failed because of a problem with the communications
link or with the host LU.
LUA_RECEIVED_UNBIND
This return code indicates that the host sent an UNBIND command to end the session.
This value can occur only if the SLI_OPEN verb for this session specified
lua_session_type
LUA_SESSION_TYPE_DEDICATED.
LUA_RUI_LOGIC_ERROR
This return code indicates one of the following:
• The host system has violated SNA protocols
• An internal error was detected within LUA
Attempt to reproduce the problem with SNA tracing active (contact your System Administrator if
necessary), and check that the host is sending correct data. If this does not solve the problem, contact
your SNAplus2 support personnel.
lua_prim_rc
LUA_INVALID_VERB
Either the lua_verb parameter or the lua_opcode parameter was not valid. The verb did not execute.
WINDOWS
lua_prim_rc
LUA_STACK_TOO_SMALL
The stack size of the application is too small for LUA to complete the request. Increase the stack size
of your application.
lua_prim_rc
LUA_UNEXPECTED_DOS_ERROR
An operating system error occurred.
lua_sec_rc
110