HP-UX SNAplus2 R7 Administration Command Reference

Administration Commands
start_internal_pu
primary_rc
STATE_CHECK
secondary_rc
DLC_DEACTIVATING
The specied DLC has already been started, and is being deactivated.
Other Conditions
Appendix A, Common Return Codes from snapadmin Commands, lists combinations of primary and secondary
return codes that are common to all commands.
2.195 start_internal_pu
The start_internal_pu command requests DLUR to initiate SSCP-PU session activation for a previously
dened local PU that is served by DLUR.
This command must be issued to a running node.
2.195.1 Supplied Parameters
Parameter name Type Length Default
[start_internal_pu]
pu_name character 8
dlus_name character 17 (null string)
bkup_dlus_name character 17 (null string)
Supplied parameters are:
pu_name
Name of the internal PU to be started. This PU must have been previously dened using de-
fine_internal_pu. The name is a type-A character string starting with a letter.
dlus_name
Name of the DLUS node that DLUR will contact to solicit SSCP-PU session activation for the given PU.
Specify 317 type-A characters, consisting of a 18 character network name, followed by a period, followed
by a 18 character DLUS node name.
To use the DLUS specied in define_internal_pu, or the global default specied in de-
fine_dlur_defaults if no DLUS was specied in define_internal_pu, do not specify this
parameter.
bkup_dlus_name
Name of the DLUS node that DLUR will store as the backup DLUS for the given PU. Specify 317 type-A
characters, consisting of a 18 character network name, followed by a period, followed by a 18 character
backup DLUS name.
To use the backup DLUS specied in define_internal_pu, or the global backup default specied in
define_dlur_defaults if no backup DLUS was specied in define_internal_pu, do not specify
this parameter.
2.195.2 Returned Parameters
No parameters are returned by SNAplus2 when this command executes successfully.