HP-UX SNAplus2 NOF Programmer's Guide
NOF API Verbs (QUERY Verbs)
QUERY_MDS_APPLICATION
Chapter 4804
The size of the returned mds_application_data
structure, and therefore the offset to the start of the
next entry in the data buffer.
mds_application_data.application
Name of registered application. This is an 8-byte
type-A EBCDIC string, padded on the right with spaces
if the name is shorter than 8 characters.
mds_application_data.max_rcv_size
The maximum number of bytes that the application
can receive in one message (this is specified when an
application registers with MDS). For more information
about MDS-level application registration, refer to the
HP-UX SNAplus2 MS Programmers Guide.
Returned Parameters: Parameter Check
If the verb does not execute because of a parameter error, SNAplus2
returns the following parameters:
primary_rc
AP_PARAMETER_CHECK
secondary_rc
Possible values are:
AP_INVALID_APPLICATION_NAME
The
list_options
parameter was
set to AP_LIST_INCLUSIVE to list all
entries starting from the supplied
name, but the
application
parameter was not valid.
AP_INVALID_LIST_OPTION
The
list_options
parameter was
not set to a valid value.
Appendix A, “Common Return Codes,” lists further secondary return
codes associated with AP_PARAMETER_CHECK, which are common to all
NOF verbs.