HP-UX SNAplus2 NOF Programmer's Guide

NOF Indications
DOWNSTREAM_LU_INDICATION
Chapter 61128
Current size of the receive pacing window on this
session. (In the LU-SSCP session statistics, this
parameter is reserved.)
send_data_frames
Number of normal flow data frames sent.
send_fmd_data_frames
Number of normal flow FMD data frames sent.
send_data_bytes
Number of normal flow data bytes sent.
rcv_data_frames
Number of normal flow data frames received.
rcv_fmd_data_frames
Number of normal flow FMD data frames received.
rcv_data_bytes
Number of normal flow data bytes received.
sidh
Session ID high byte. (In the upstream PLU-SLU
session statistics, this parameter is reserved.)
sidl
Session ID low byte. (In the upstream PLU-SLU
session statistics, this parameter is reserved.)
odai
Origin Destination Assignor Indicator. When bringing
up a session, the sender of the BIND sets this field to
zero if the local node contains the primary link station,
and sets it to one if the BIND sender is the node
containing the secondary linkstation. (In the upstream
PLU-SLU session statistics, this parameter is
reserved.)
ls_name