HP-UX SNAplus2 MS Programmer's Guide
Management Services Verbs
REGISTER_NMVT_APPLICATION
Chapter 366
opcode
AP_REGISTER_NMVT_APPLICATION
ms_appl_name
A name identifying this application. An application can
register more than once using different application
names. This name has the following requirements:
• It cannot match the name used by any other
application that is currently registered to accept
the same range of keys as specified by the
ms_vector_key_type
parameter.
• It cannot be either NODE and UNIX, which are
reserved for use by SNAplus2 components.
• It must be eight characters long; pad on the right
with EBCDIC space characters (0x40) if necessary.
• It can be one of the following:
— An EBCDIC string, using type-1134 characters
(uppercase A–Z and numerals 0–9)
— One of the MS Discipline-Specific Application
Programs specified in an appendix of IBM
Systems Network Architecture: Management
Services Reference
Incoming NMVTs will be routed to this application
only if the value specified in this parameter matches
the Destination Application Name (0x50) subfield of
the MS major vector within the NMVT.
ms_vector_key_type
The MS major vector key or keys accepted by the
application. SNAplus2 routes incoming NMVTs to the
application that issued this verb only if the MS major
vector key in the NMVT matches the value or values
specified here.
Specify one of the following:
0x
nnnn